{"title":"Battery Fuses and Holders","description":"\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eBattery fuses and holders\u003c\/strong\u003e protect batteries from overcurrents in solar systems. They are essential for extending battery lifespan and ensuring safety.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eBenefits:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePrevent damage to batteries\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eExtend battery life\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eProtect home or business from electrical fires\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eKeep solar system running smoothly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWhen choosing:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eConsider voltage and amperage of batteries\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eChoose high-quality materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eGet battery fuses and holders for your solar system.\u003c\/strong\u003e They are an essential investment for safety and peace of mind.\u003c\/p\u003e","products":[{"product_id":"modular-fuse-holder-for-mega-fuse","title":"Modular fuse holder for MEGA-fuse","description":"\u003cp\u003eThe Modular Fuse Holder for MEGA-fuse is a versatile and easy-to-use component designed to securely hold all MEGA fuses within the range of 60A to 300A. This fuse holder is an essential part of any energy storage or power management system, providing reliable and safe housing for MEGA fuses. It ensures stable and effective electrical connections, enhancing the safety and longevity of your DC protection setup.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with MEGA Fuses:\u003c\/strong\u003e Designed to accommodate all MEGA fuses from 60A to 300A, offering flexibility across a range of applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy to Use:\u003c\/strong\u003e Simple installation and removal of fuses make maintenance and replacements quick and straightforward.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecure and Reliable:\u003c\/strong\u003e Provides a stable and secure housing for MEGA fuses, ensuring effective electrical connections and protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Application:\u003c\/strong\u003e Suitable for use in battery storage systems, inverters, and other components requiring reliable DC protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVIC-MEGA-MODULAR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStorage Systems - Battery Fuse Holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Fuse Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMEGA fuses from 60A to 300A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery storage systems, inverters, DC protection setups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Usage Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Easy to mount and install, allowing for quick integration into any battery storage or energy management system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsage:\u003c\/strong\u003e Ideal for safely housing MEGA fuses within the range of 60A to 300A, ensuring reliable DC protection for various components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompliance and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e Meets industry standards for electrical safety and fuse holder design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e [Details of warranty period and coverage].\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy Choose Modular Fuse Holder for MEGA-fuse:\u003c\/strong\u003e Offers a reliable and flexible solution for securely housing MEGA fuses in your power management system, supporting safe and efficient operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBenefits:\u003c\/strong\u003e Enhances safety, simplifies fuse replacement and maintenance, and provides compatibility across a wide range of fuse ratings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/MEGA-fuse-and-Fuse-holder-2022-04-08.pdf\" target=\"_blank\"\u003eCE Declaration of Conformity VIC-MEGA 2022\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Datasheet-Midi-Mega-and-ANL-fuses-and-fuse-holders-EN.pdf\" target=\"_blank\"\u003eData Sheet MIDI, MEGA and ANL fuses, and fuse holders\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Datasheet-Modular-MEGA-fuse-holder-and-high-current-busbar-EN.pdf\" target=\"_blank\"\u003eData Sheet Mod ular MEGA fuse holder and high current busbar\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Certificate%20Safety%20IEC60947%20MIDI%20MEGA.pdf\" target=\"_blank\"\u003eIEC Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Mega%20fuse%20Manual%20vic.pdf\" target=\"_blank\"\u003eUser Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":45322732961941,"sku":"VIC-MEGA-MODULAR","price":589.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/image-upscaled-2024-09-16T111616.395.jpg?v=1726478182"},{"product_id":"fuse-holder-for-mega-fuse","title":"Fuse holder for MEGA-fuse","description":"\u003ch3\u003eFuse Holder for MEGA-Fuse – Secure DC Protection for Your Battery Systems\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuse Holder for MEGA-Fuse\u003c\/strong\u003e (Part No: VIC-MEGA-HOLDER) is a reliable and easy-to-use fuse holder designed for DC protection between inverters, batteries, and other connected components in your battery bank. This holder ensures a secure and efficient installation, providing safety and peace of mind for your energy storage system.\u003c\/p\u003e\n\u003ch4\u003eKey Features:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Installation:\u003c\/strong\u003e Designed for simple setup, allowing for quick integration into your energy storage system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective Cover:\u003c\/strong\u003e Comes with a robust protection cover to shield the fuse, preventing accidental contact and enhancing safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Compatibility:\u003c\/strong\u003e Supports various MEGA-fuse ratings, providing flexibility to suit different system requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eIdeal for:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Protection:\u003c\/strong\u003e Perfect for use between inverters, batteries, and other connected items in a battery bank, ensuring reliable DC circuit protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEnsure safe and secure operation of your energy storage system with the \u003cstrong\u003eFuse Holder for MEGA-Fuse\u003c\/strong\u003e—a vital accessory for any battery-based energy setup.\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/MEGA-fuse-and-Fuse-holder-2022-04-08.pdf\" target=\"_blank\"\u003eCE Declaration of Conformity VIC-MEGA 2022\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Datasheet-Midi-Mega-and-ANL-fuses-and-fuse-holders-EN.pdf\" target=\"_blank\"\u003eData Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Datasheet-Midi-Mega-and-ANL-fuses-and-fuse-holders-EN.pdf\" target=\"_blank\"\u003eData Sheet MIDI, MEGA and ANL fuses, and fuse holders\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Certificate%20Safety%20IEC60947%20MIDI%20MEGA.pdf\" target=\"_blank\"\u003eIEC Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Mega%20fuse%20Manual%20vic.pdf\" target=\"_blank\"\u003eUser Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":45322732994709,"sku":"VIC-MEGA-HOLDER","price":199.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/victron_energy_fuse_holder_for_mega_fuse_cip000100001_1657271384.webp?v=1725019351"},{"product_id":"busbar-to-connect-6-vic-mega-holder","title":"Busbar to connect 6 VIC-MEGA-HOLDER","description":"\u003ch3\u003eBusbar to Connect 6 VIC-MEGA-HOLDER - High-Current Distribution for Energy Storage Systems\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePart No:\u003c\/strong\u003e VIC-MEGA-BUSBAR-6\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Storage Systems - Battery Fuse Holder\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Busbar to connect 6 VIC-MEGA-HOLDER is designed to provide efficient high-current distribution in energy storage and DC power systems. This robust busbar supports the connection of six VIC-MEGA fuse holders, allowing each connected device to have individual 250A protection while consolidating power into a single 1500A output. It is constructed from high-quality copper to ensure excellent conductivity and durability in demanding environments.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Current Capacity:\u003c\/strong\u003e Rated for up to 1500A, allowing for the distribution of significant power across multiple devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient Design:\u003c\/strong\u003e Supports up to 6 devices with individual fuses, offering 250A protection per device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Configuration:\u003c\/strong\u003e Compatible with VIC-MEGA fuse holders (not included), making it adaptable to a variety of power setups.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Made from copper (40 x 5 mm) to ensure reliable high-current handling and long-term durability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 VIC-MEGA fuse holders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Per Device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCopper (40 x 5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery and DC power systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVIC-MEGA-BUSBAR-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eInstallation and Usage:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThis busbar is ideal for applications requiring high-current distribution, such as energy storage systems, where multiple devices need individual fuses. It connects up to 6 VIC-MEGA fuse holders to provide distributed protection with a consolidated high-current output. Proper installation by a qualified technician is required for safe and effective use.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eImportant Notes:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure that the system’s current and voltage ratings are compatible with the busbar before installation.\u003c\/li\u003e\n\u003cli\u003eThe modular mega fuse holders and fuses are not included and must be purchased separately.\u003c\/li\u003e\n\u003cli\u003eInstallation must comply with local electrical regulations and standards to ensure safety and functionality.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Busbar to connect 6 VIC-MEGA-HOLDER provides a powerful and efficient solution for organizing and protecting high-current circuits in energy storage and DC systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/MEGA-fuse-and-Fuse-holder-2022-04-08.pdf\" target=\"_blank\"\u003eCE Declaration of Conformity VIC-MEGA 2022\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Datasheet-Midi-Mega-and-ANL-fuses-and-fuse-holders-EN.pdf\" target=\"_blank\"\u003eData Sheet MIDI, MEGA and ANL fuses, and fuse holders\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Datasheet-Modular-MEGA-fuse-holder-and-high-current-busbar-EN.pdf\" target=\"_blank\"\u003eData Sheet Mod ular MEGA fuse holder and high current busbar\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Certificate%20Safety%20IEC60947%20MIDI%20MEGA.pdf\" target=\"_blank\"\u003eIEC Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Mega%20fuse%20Manual%20vic.pdf\" target=\"_blank\"\u003eUser Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":45322733027477,"sku":"VIC-MEGA-BUSBAR-6","price":739.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/165578daae447a.png?v=1724664480"},{"product_id":"busbar-to-connect-5-vic-mega-holder","title":"Busbar to connect 5 VIC-MEGA-HOLDER","description":"\u003ch3\u003eBusbar to Connect 5 VIC-MEGA-HOLDER - Efficient High-Current Power Distribution\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePart No:\u003c\/strong\u003e VIC-MEGA-BUSBAR-5\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Storage Systems - Battery Fuse Holder\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Busbar to connect 5 VIC-MEGA-HOLDER is a high-current power distribution component designed for use with multiple VIC-MEGA fuse holders. This busbar allows for efficient and organized connection of up to 5 fuse holders in battery or DC power systems. Its robust design ensures safe and reliable operation in demanding environments.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient Power Distribution:\u003c\/strong\u003e Supports the connection of 5 VIC-MEGA fuse holders, enabling streamlined high-current distribution across multiple devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Current Capability:\u003c\/strong\u003e Engineered to handle substantial current loads, ensuring safe and stable operation for energy storage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Built to endure the rigors of heavy-duty applications, providing long-lasting reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Helps reduce installation space and simplifies the wiring process for large energy storage setups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 VIC-MEGA fuse holders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVIC-MEGA-HOLDER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery and DC power systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVIC-MEGA-BUSBAR-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eInstallation and Usage:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThis busbar is designed to simplify the wiring and connection of VIC-MEGA fuse holders in high-current battery and DC power systems. Installation must be carried out by a qualified electrician or technician to ensure proper safety and performance.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eImportant Notes:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure compatibility with the system’s current and voltage ratings before installation.\u003c\/li\u003e\n\u003cli\u003eFollow local electrical regulations and standards for safe and effective installation.\u003c\/li\u003e\n\u003cli\u003eProper installation by a qualified technician is essential for maintaining system safety and functionality.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Busbar to connect 5 VIC-MEGA-HOLDER provides a streamlined solution for organizing and distributing high-current power within energy storage and DC systems.\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/MEGA-fuse-and-Fuse-holder-2022-04-08.pdf\" target=\"_blank\"\u003eCE Declaration of Conformity VIC-MEGA 2022\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Datasheet-Midi-Mega-and-ANL-fuses-and-fuse-holders-EN.pdf\" target=\"_blank\"\u003eData Sheet MIDI, MEGA and ANL fuses, and fuse holders\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Datasheet-Modular-MEGA-fuse-holder-and-high-current-busbar-EN.pdf\" target=\"_blank\"\u003eData Sheet Mod ular MEGA fuse holder and high current busbar\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Certificate%20Safety%20IEC60947%20MIDI%20MEGA.pdf\" target=\"_blank\"\u003eIEC Certificate\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Mega%20fuse%20Manual%20vic.pdf\" target=\"_blank\"\u003eUser Manual\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":45322733125781,"sku":"VIC-MEGA-BUSBAR-5","price":639.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/CIP100400060_500x_bef049ac-0773-4b5d-bd83-e983424d4581.jpg?v=1724664119"},{"product_id":"mega-fuse-300a-58v-for-48v-products-1-pc","title":"MEGA-fuse 300A\/58V for 48V products (1 pc)","description":"\u003cp\u003eThe MEGA-fuse 300A\/58V is a heavy-duty fuse designed specifically for DC protection in 48V battery storage systems. Part of the Victron fuse range, this fuse provides robust protection for inverters, batteries, and other components within a battery bank. With a protective cover and precise specifications, it ensures safe and efficient operation for your solar power or energy storage system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized for 48V Products:\u003c\/strong\u003e Delivers 300A\/58V DC protection, ideal for safeguarding components in 48V battery storage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective Fuse Cover:\u003c\/strong\u003e Comes with a protective cover to prevent accidental contact, ensuring safe and secure installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetailed Specifications:\u003c\/strong\u003e Voltage drop and current ratings are clearly specified for each fuse, ensuring accurate and reliable protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Resistance Information:\u003c\/strong\u003e Cold resistance values are provided on the datasheet for precise application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Range Options:\u003c\/strong\u003e Part of the Victron fuse range, available in three types: MIDI, MEGA, and ANL, as described in the datasheet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVIC-MEGA-300A-58V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC Protection Fuse for 48V Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e58V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48V battery storage systems, inverters, battery banks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse with protective cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Information\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCold resistance and voltage drop specified on datasheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Usage Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Easily installed in any 48V battery bank or solar power system to provide reliable DC protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsage:\u003c\/strong\u003e Ideal for protecting DC circuits and components in energy storage systems designed for 48V products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance:\u003c\/strong\u003e Regular inspections are recommended to ensure continued safe operation and optimal performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompliance and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e Conforms to industry standards for electrical safety and DC protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e [Details of warranty period and coverage].\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy Choose MEGA-fuse 300A\/58V for 48V Products:\u003c\/strong\u003e Provides a robust and reliable solution for protecting 48V battery storage systems, with detailed specifications for safe and precise application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBenefits:\u003c\/strong\u003e Comes with a protective cover for added safety and is part of a comprehensive range of fuses to meet various DC protection needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/MEGA-fuse-and-Fuse-holder-2022-04-08.pdf\" target=\"_blank\"\u003eCE Declaration of Conformity VIC-MEGA 2022\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Datasheet-Midi-Mega-and-ANL-fuses-and-fuse-holders-EN.pdf\" target=\"_blank\"\u003eData Sheet MIDI, MEGA and ANL fuses, and fuse holders\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Certificate%20Safety%20IEC60947%20MIDI%20MEGA.pdf\" target=\"_blank\"\u003eIEC Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Mega%20fuse%20Manual%20vic.pdf\" target=\"_blank\"\u003eUser Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":45322733158549,"sku":"VIC-MEGA-300A-58V","price":519.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/image-upscaled-2024-09-16T104946.891_61e105b3-00fa-4653-b225-c2105fe4063f.jpg?v=1726476707"},{"product_id":"mega-fuse-200a-58v-for-48v-products-1-pc","title":"MEGA-fuse 200A\/58V for 48V products (1 pc)","description":"\u003cp\u003eThe MEGA-fuse 200A\/58V is a high-performance fuse designed specifically for DC protection in 48V battery storage systems. Part of the Victron fuse range, this fuse offers reliable and efficient protection for inverters, batteries, and other components connected to a battery bank. With a protective cover and detailed specifications, it ensures safe and effective operation of your solar power or energy storage system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized for 48V Products:\u003c\/strong\u003e Designed to provide 200A\/58V DC protection, ideal for use in 48V battery storage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective Fuse Cover:\u003c\/strong\u003e Includes a cover for enhanced safety, preventing accidental contact and ensuring secure installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetailed Specifications:\u003c\/strong\u003e Voltage drop and current ratings are specified for each fuse, ensuring precise protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Resistance Information:\u003c\/strong\u003e Each fuse's cold resistance is listed on the datasheet for accurate application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart of a Comprehensive Range:\u003c\/strong\u003e Available in three ranges: MIDI, MEGA, and ANL, as detailed in the datasheet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVIC-MEGA-200A-58V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC Protection Fuse for 48V Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e58V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48V battery storage systems, inverters, battery banks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse with protective cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Information\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCold resistance and voltage drop specified on datasheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Usage Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Easily installed in any 48V battery bank or solar power system to provide reliable DC protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsage:\u003c\/strong\u003e Suitable for safeguarding DC circuits and components in energy storage systems designed for 48V products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance:\u003c\/strong\u003e Regular inspection is recommended to maintain optimal safety and performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompliance and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e Meets industry standards for electrical safety and DC protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e [Details of warranty period and coverage].\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy Choose MEGA-fuse 200A\/58V for 48V Products:\u003c\/strong\u003e Provides a tailored solution for protecting 48V battery storage systems, with detailed specifications for accurate and safe application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBenefits:\u003c\/strong\u003e Comes with a protective cover and is part of a comprehensive range of fuses to suit different DC protection needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/MEGA-fuse-and-Fuse-holder-2022-04-08.pdf\" target=\"_blank\"\u003eCE Declaration of Conformity VIC-MEGA 2022\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Datasheet-Midi-Mega-and-ANL-fuses-and-fuse-holders-EN.pdf\" target=\"_blank\"\u003eData Sheet MIDI, MEGA and ANL fuses, and fuse holders\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Certificate%20Safety%20IEC60947%20MIDI%20MEGA.pdf\" target=\"_blank\"\u003eIEC Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Mega%20fuse%20Manual%20vic.pdf\" target=\"_blank\"\u003eUser Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":45322733224085,"sku":"VIC-MEGA-200A-58V","price":489.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/mega-fuse-victron-60a-500a-32v-and-125-300a-58v_df668ca9-92da-41a2-980a-7824d5cf0943.webp?v=1726476450"},{"product_id":"mega-fuse-150a-32v-1-pc","title":"MEGA-fuse 150A\/32V (1 pc)","description":"\u003cp\u003eThe MEGA-fuse 150A\/32V is a robust and reliable fuse designed for DC protection in battery storage systems. Part of the Victron fuse range, this fuse is ideal for protecting inverters, batteries, and other components in a battery bank. With detailed specifications and a protective cover, it ensures safe and efficient operation of your solar power or energy storage system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Protection Rating:\u003c\/strong\u003e Provides 150A\/32V DC protection, suitable for use in battery storage systems, inverters, and other DC components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective Fuse Cover:\u003c\/strong\u003e Includes a durable cover for enhanced safety, preventing accidental contact and ensuring secure installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetailed Specifications:\u003c\/strong\u003e Voltage drop and current ratings are specified for each fuse to ensure precise protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Resistance Information:\u003c\/strong\u003e Each fuse's cold resistance is listed on the datasheet for accurate application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart of a Comprehensive Range:\u003c\/strong\u003e Available in three ranges: MIDI, MEGA, and ANL, as detailed in the datasheet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVIC-MEGA-150A-32V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC Protection Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery storage systems, inverters, battery banks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse with protective cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Information\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCold resistance and voltage drop specified on datasheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Usage Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Easy to install in any battery bank or solar power system to provide reliable DC protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsage:\u003c\/strong\u003e Ideal for protecting DC circuits and components in energy storage systems, ensuring continued safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance:\u003c\/strong\u003e Regular inspections recommended to maintain optimal safety and performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompliance and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e Conforms to industry standards for electrical safety and DC protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e [Details of warranty period and coverage].\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy Choose MEGA-fuse 150A\/32V:\u003c\/strong\u003e Provides a high-performance solution for DC protection in solar power and battery storage systems, with detailed specifications for precise application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBenefits:\u003c\/strong\u003e Comes with a protective cover for added safety and is part of a comprehensive range of fuses to meet various DC protection needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Datasheet-Midi-Mega-and-ANL-fuses-and-fuse-holders-EN.pdf\" target=\"_blank\"\u003eData Sheet MIDI, MEGA and ANL fuses, and fuse holders\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Certificate%20Safety%20IEC60947%20MIDI%20MEGA.pdf\" target=\"_blank\"\u003eIEC Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Mega%20fuse%20Manual%20vic.pdf\" target=\"_blank\"\u003eUser Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":45322733420693,"sku":"VIC-MEGA-150A-32V","price":49.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/mega-fuse-victron-60a-500a-32v-and-125-300a-58v_54cd2655-266c-46fe-8321-3b19c5a7b2f1.webp?v=1726476285"},{"product_id":"mega-fuse-125a-58v-for-48v-products-1-pc","title":"MEGA-fuse 125A\/58V for 48V products (1 pc)","description":"\u003cp\u003eThe MEGA-fuse 125A\/58V is specifically designed for DC protection in 48V battery storage systems. Part of the Victron fuse range, this fuse offers reliable and efficient protection for inverters, batteries, and other components connected to a battery bank. With a protective cover and detailed specifications, this fuse ensures safe and effective operation for your solar power or energy storage system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized for 48V Products:\u003c\/strong\u003e Designed to provide 125A\/58V DC protection, ideal for use in 48V battery storage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective Fuse Cover:\u003c\/strong\u003e Includes a cover for enhanced safety, preventing accidental contact and ensuring secure installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetailed Specifications:\u003c\/strong\u003e Voltage drop and current ratings are specified for each fuse, ensuring precise protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Resistance Specified:\u003c\/strong\u003e Each fuse's cold resistance is detailed on the datasheet for accurate application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart of a Comprehensive Range:\u003c\/strong\u003e Available in three ranges: MIDI, MEGA, and ANL, as described in the datasheet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVIC-MEGA-125A-58V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC Protection Fuse for 48V Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e58V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48V battery storage systems, inverters, battery banks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse with protective cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Information\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCold resistance and voltage drop specified on datasheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Usage Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Easily installed in any 48V battery bank or solar power system to provide reliable DC protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsage:\u003c\/strong\u003e Suitable for safeguarding DC circuits and components in energy storage systems designed for 48V products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance:\u003c\/strong\u003e Regular inspection is recommended to maintain optimal safety and performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompliance and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e Meets industry standards for electrical safety and DC protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e [Details of warranty period and coverage].\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy Choose MEGA-fuse 125A\/58V for 48V Products:\u003c\/strong\u003e Provides a tailored solution for protecting 48V battery storage systems, with detailed specifications for accurate and safe application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBenefits:\u003c\/strong\u003e Comes with a protective cover and is part of a comprehensive range of fuses to suit different DC protection needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/MEGA-fuse-and-Fuse-holder-2022-04-08.pdf\" target=\"_blank\"\u003eCE Declaration of Conformity VIC-MEGA 2022\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Datasheet-Midi-Mega-and-ANL-fuses-and-fuse-holders-EN.pdf\" target=\"_blank\"\u003eData Sheet MIDI, MEGA and ANL fuses, and fuse holders\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Certificate%20Safety%20IEC60947%20MIDI%20MEGA.pdf\" target=\"_blank\"\u003eIEC Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Mega%20fuse%20Manual%20vic.pdf\" target=\"_blank\"\u003eUser Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":45322733486229,"sku":"VIC-MEGA-125A-58V","price":489.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/mega-fuse-victron-60a-500a-32v-and-125-300a-58v_07c32505-83ce-43c1-91e5-0ba11ea8283d.webp?v=1726476178"},{"product_id":"mega-fuse-125a-32v-1pc","title":"MEGA-fuse 125A\/32V (1pc)","description":"\u003cdiv class=\"flex-shrink-0 flex flex-col relative items-end\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"pt-0\"\u003e\n\u003cdiv class=\"gizmo-bot-avatar flex h-8 w-8 items-center justify-center overflow-hidden rounded-full\"\u003e\n\u003cdiv class=\"relative p-1 rounded-sm flex items-center justify-center bg-token-main-surface-primary text-token-text-primary h-8 w-8\"\u003e\u003csvg width=\"41\" height=\"41\" viewbox=\"0 0 41 41\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"icon-md\" role=\"img\"\u003e\u003ctext x=\"-9999\" y=\"-9999\"\u003e\u003c\/text\u003e\u003cpath d=\"M37.5324 16.8707C37.9808 15.5241 38.1363 14.0974 37.9886 12.6859C37.8409 11.2744 37.3934 9.91076 36.676 8.68622C35.6126 6.83404 33.9882 5.3676 32.0373 4.4985C30.0864 3.62941 27.9098 3.40259 25.8215 3.85078C24.8796 2.7893 23.7219 1.94125 22.4257 1.36341C21.1295 0.785575 19.7249 0.491269 18.3058 0.500197C16.1708 0.495044 14.0893 1.16803 12.3614 2.42214C10.6335 3.67624 9.34853 5.44666 8.6917 7.47815C7.30085 7.76286 5.98686 8.3414 4.8377 9.17505C3.68854 10.0087 2.73073 11.0782 2.02839 12.312C0.956464 14.1591 0.498905 16.2988 0.721698 18.4228C0.944492 20.5467 1.83612 22.5449 3.268 24.1293C2.81966 25.4759 2.66413 26.9026 2.81182 28.3141C2.95951 29.7256 3.40701 31.0892 4.12437 32.3138C5.18791 34.1659 6.8123 35.6322 8.76321 36.5013C10.7141 37.3704 12.8907 37.5973 14.9789 37.1492C15.9208 38.2107 17.0786 39.0587 18.3747 39.6366C19.6709 40.2144 21.0755 40.5087 22.4946 40.4998C24.6307 40.5054 26.7133 39.8321 28.4418 38.5772C30.1704 37.3223 31.4556 35.5506 32.1119 33.5179C33.5027 33.2332 34.8167 32.6547 35.9659 31.821C37.115 30.9874 38.0728 29.9178 38.7752 28.684C39.8458 26.8371 40.3023 24.6979 40.0789 22.5748C39.8556 20.4517 38.9639 18.4544 37.5324 16.8707ZM22.4978 37.8849C20.7443 37.8874 19.0459 37.2733 17.6994 36.1501C17.7601 36.117 17.8666 36.0586 17.936 36.0161L25.9004 31.4156C26.1003 31.3019 26.2663 31.137 26.3813 30.9378C26.4964 30.7386 26.5563 30.5124 26.5549 30.2825V19.0542L29.9213 20.998C29.9389 21.0068 29.9541 21.0198 29.9656 21.0359C29.977 21.052 29.9842 21.0707 29.9867 21.0902V30.3889C29.9842 32.375 29.1946 34.2791 27.7909 35.6841C26.3872 37.0892 24.4838 37.8806 22.4978 37.8849ZM6.39227 31.0064C5.51397 29.4888 5.19742 27.7107 5.49804 25.9832C5.55718 26.0187 5.66048 26.0818 5.73461 26.1244L13.699 30.7248C13.8975 30.8408 14.1233 30.902 14.3532 30.902C14.583 30.902 14.8088 30.8408 15.0073 30.7248L24.731 25.1103V28.9979C24.7321 29.0177 24.7283 29.0376 24.7199 29.0556C24.7115 29.0736 24.6988 29.0893 24.6829 29.1012L16.6317 33.7497C14.9096 34.7416 12.8643 35.0097 10.9447 34.4954C9.02506 33.9811 7.38785 32.7263 6.39227 31.0064ZM4.29707 13.6194C5.17156 12.0998 6.55279 10.9364 8.19885 10.3327C8.19885 10.4013 8.19491 10.5228 8.19491 10.6071V19.808C8.19351 20.0378 8.25334 20.2638 8.36823 20.4629C8.48312 20.6619 8.64893 20.8267 8.84863 20.9404L18.5723 26.5542L15.206 28.4979C15.1894 28.5089 15.1703 28.5155 15.1505 28.5173C15.1307 28.5191 15.1107 28.516 15.0924 28.5082L7.04046 23.8557C5.32135 22.8601 4.06716 21.2235 3.55289 19.3046C3.03862 17.3858 3.30624 15.3413 4.29707 13.6194ZM31.955 20.0556L22.2312 14.4411L25.5976 12.4981C25.6142 12.4872 25.6333 12.4805 25.6531 12.4787C25.6729 12.4769 25.6928 12.4801 25.7111 12.4879L33.7631 17.1364C34.9967 17.849 36.0017 18.8982 36.6606 20.1613C37.3194 21.4244 37.6047 22.849 37.4832 24.2684C37.3617 25.6878 36.8382 27.0432 35.9743 28.1759C35.1103 29.3086 33.9415 30.1717 32.6047 30.6641C32.6047 30.5947 32.6047 30.4733 32.6047 30.3889V21.188C32.6066 20.9586 32.5474 20.7328 32.4332 20.5338C32.319 20.3348 32.154 20.1698 31.955 20.0556ZM35.3055 15.0128C35.2464 14.9765 35.1431 14.9142 35.069 14.8717L27.1045 10.2712C26.906 10.1554 26.6803 10.0943 26.4504 10.0943C26.2206 10.0943 25.9948 10.1554 25.7963 10.2712L16.0726 15.8858V11.9982C16.0715 11.9783 16.0753 11.9585 16.0837 11.9405C16.0921 11.9225 16.1048 11.9068 16.1207 11.8949L24.1719 7.25025C25.4053 6.53903 26.8158 6.19376 28.2383 6.25482C29.6608 6.31589 31.0364 6.78077 32.2044 7.59508C33.3723 8.40939 34.2842 9.53945 34.8334 10.8531C35.3826 12.1667 35.5464 13.6095 35.3055 15.0128ZM14.2424 21.9419L10.8752 19.9981C10.8576 19.9893 10.8423 19.9763 10.8309 19.9602C10.8195 19.9441 10.8122 19.9254 10.8098 19.9058V10.6071C10.8107 9.18295 11.2173 7.78848 11.9819 6.58696C12.7466 5.38544 13.8377 4.42659 15.1275 3.82264C16.4173 3.21869 17.8524 2.99464 19.2649 3.1767C20.6775 3.35876 22.0089 3.93941 23.1034 4.85067C23.0427 4.88379 22.937 4.94215 22.8668 4.98473L14.9024 9.58517C14.7025 9.69878 14.5366 9.86356 14.4215 10.0626C14.3065 10.2616 14.2466 10.4877 14.2479 10.7175L14.2424 21.9419ZM16.071 17.9991L20.4018 15.4978L24.7325 17.9975V22.9985L20.4018 25.4983L16.071 22.9985V17.9991Z\" fill=\"currentColor\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"group\/conversation-turn relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex-col gap-1 md:gap-3\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col flex-grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"30317052-09fd-47b2-b946-e6a5ecaa6585\" dir=\"auto\" class=\"min-h-[20px] text-message flex w-full flex-col items-end gap-2 whitespace-normal break-words [.text-message+\u0026amp;]:mt-5\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[3px]\"\u003e\n\u003cdiv class=\"result-streaming markdown prose w-full break-words dark:prose-invert light\"\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Title: MEGA-fuse 125A\/32V (1 pc)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe MEGA-fuse 125A\/32V is a reliable fuse designed to provide DC protection in battery storage systems. Ideal for use between inverters, batteries, and other connected components in a battery bank, this fuse ensures safe and efficient operation of your solar power system. With an easy installation process and a protective cover, it offers a dependable solution for safeguarding your electrical circuits.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Protection Rating:\u003c\/strong\u003e Provides 125A\/32V DC protection, suitable for use between inverters, batteries, and other items in a battery bank.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Installation:\u003c\/strong\u003e Simple, user-friendly design for quick installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Protection Cover:\u003c\/strong\u003e Includes a cover to ensure safe operation by protecting the fuse.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Ratings Available:\u003c\/strong\u003e Available in various ratings to accommodate different system requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVIC-MEGA-125A-32V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC Protection Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery storage systems, inverters, battery banks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse with protection cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Usage Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Easily installed in any battery bank or solar power system to provide essential protection between inverters and batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsage:\u003c\/strong\u003e Suitable for protecting DC circuits and components in energy storage and solar power systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance:\u003c\/strong\u003e Regular inspections are recommended to ensure continued safe operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompliance and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e Meets industry standards for electrical safety and DC protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e [Details of warranty period and coverage].\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy Choose MEGA-fuse 125A\/32V:\u003c\/strong\u003e Provides a reliable, easy-to-install solution for DC protection in solar power and battery storage systems, enhancing safety and system longevity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBenefits:\u003c\/strong\u003e Comes with a protective cover for added safety and is available in various ratings to suit specific system needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/MEGA-fuse-and-Fuse-holder-2022-04-08.pdf\" target=\"_blank\"\u003eCE Declaration of Conformity VIC-MEGA 2022\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Datasheet-Midi-Mega-and-ANL-fuses-and-fuse-holders-EN.pdf\" target=\"_blank\"\u003eData Sheet MIDI, MEGA and ANL fuses, and fuse holders\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Certificate%20Safety%20IEC60947%20MIDI%20MEGA.pdf\" target=\"_blank\"\u003eIEC Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Mega%20fuse%20Manual%20vic.pdf\" target=\"_blank\"\u003eUser Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":45322733551765,"sku":"VIC-MEGA-125A-32V","price":39.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/mega-fuse-victron-60a-500a-32v-and-125-300a-58v_10361d97-8ae2-417b-8582-8012f46be71c.webp?v=1726475015"},{"product_id":"mega-fuse-100a-32v-1-pc","title":"MEGA-fuse 100A\/32V (1 pc)","description":"\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"intro\" data-mce-fragment=\"1\"\u003e\n\u003cp\u003eThe MEGA-fuse 100A\/32V is an essential component for providing reliable DC protection in battery storage systems. Designed for use between inverters, batteries, and other connected components in a battery bank, this fuse offers a straightforward and secure solution for safeguarding your solar power system. With a robust design and easy installation process, it is an ideal choice for both residential and commercial energy setups.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Protection Rating:\u003c\/strong\u003e Provides 100A\/32V DC protection, ideal for use between inverters, batteries, and other connected items in a battery bank.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Installation:\u003c\/strong\u003e User-friendly design allows for quick and simple installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Protection Cover:\u003c\/strong\u003e Includes a protection cover to ensure safe and secure operation by covering the fuse.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Ratings Available:\u003c\/strong\u003e Comes in various ratings to suit different system requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVIC-MEGA-100A-32V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC Protection Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery storage systems, inverters, battery banks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse with protection cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Usage Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Easy to install in any battery bank or solar power system, providing essential protection between the inverter and battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsage:\u003c\/strong\u003e Suitable for protecting DC circuits and components in energy storage and solar power systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance:\u003c\/strong\u003e Regularly inspect for signs of wear or damage to ensure continued safe operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompliance and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e Meets industry standards for electrical safety and DC protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e [Details of warranty period and coverage].\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy Choose MEGA-fuse 100A\/32V:\u003c\/strong\u003e Provides reliable and easy-to-install DC protection for your solar power and battery storage systems, enhancing safety and longevity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBenefits:\u003c\/strong\u003e Comes with a protection cover for added safety, and is available in various ratings to meet specific system needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/MEGA-fuse-and-Fuse-holder-2022-04-08.pdf\" target=\"_blank\"\u003eCE Declaration of Conformity VIC-MEGA 2022\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Datasheet-Midi-Mega-and-ANL-fuses-and-fuse-holders-EN.pdf\" target=\"_blank\"\u003eData Sheet MIDI, MEGA and ANL fuses, and fuse holders\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Certificate%20Safety%20IEC60947%20MIDI%20MEGA.pdf\" target=\"_blank\"\u003eIEC Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Mega%20fuse%20Manual%20vic.pdf\" target=\"_blank\"\u003eUser Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cbr\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":45322733682837,"sku":"VIC-MEGA-100A-32V","price":49.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/mega-fuse-victron-60a-500a-32v-and-125-300a-58v.webp?v=1726474869"},{"product_id":"lynx-shunt-ve-can","title":"Lynx Shunt VE.Can","description":"\u003cp\u003eThe \u003cstrong\u003eLynx Shunt VE.Can (Part No: VIC-LYNX-SHUNT-VE-CAN)\u003c\/strong\u003e is a crucial component designed for high-current DC distribution in battery systems. It provides reliable connections for batteries and\/or DC equipment, ensuring safe and efficient power management. This shunt is ideal for use in storage systems, offering a range of models with different current ratings and connection terminals to suit various installation needs. Each busbar is equipped with a removable protection cover for enhanced safety.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAvailable Models:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e150A \/ 70V:\u003c\/strong\u003e 6 high current connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e250A \/ 70V:\u003c\/strong\u003e 4 high current connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e600A \/ 70V:\u003c\/strong\u003e 8 high current connections and 8 low current connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Applications:\u003c\/strong\u003e Suitable for high-current DC distribution and battery management systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple Connection Options:\u003c\/strong\u003e Available in models with varying current ratings and connection terminals to meet specific requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First:\u003c\/strong\u003e Includes a removable protection cover for added safety during installation and maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Built to high-quality standards for reliable and long-lasting performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Requirements:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis product must be installed by a qualified electrician or technician. All installations must comply with local wiring regulations and standards to ensure safety and optimal performance.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eImportant Information:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e Damage resulting from improper installation, handling, or unauthorized modifications may void the warranty. Ensure all installations are carried out according to local regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Lynx-DC-distribution_A.pdf\" target=\"_blank\"\u003eCE Declaration of Conformity\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Lynx_Shunt_VE_Can.pdf\" target=\"_blank\"\u003eData Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/ISO9001-certificate-2018%20(2).pdf\" target=\"_blank\"\u003eISO 9001\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":45322733715605,"sku":"VIC-LYNX-SHUNT-VE-CAN","price":5859.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/victron-lynx-shunt-vecan.jpg?v=1726214253"},{"product_id":"lynx-power-in","title":"Lynx Power In","description":"\u003cp data-mce-fragment=\"1\"\u003eThe Lynx Distribution System is a modular busbar system that incorporates DC connections, distribution, fusing, battery monitoring and\/or Lithium battery management   Product Features:\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"intro\" data-mce-fragment=\"1\"\u003eLynx Power In - A positive and negative busbar with 4 connections for batteries or DC equipment.\u003c\/li\u003e\n\u003cli class=\"intro\" data-mce-fragment=\"1\"\u003e Lynx Distributor - A positive and negative busbar with 4 fused connections for batteries or DC equipment together with fuse monitoring.\u003c\/li\u003e\n\u003cli class=\"intro\" data-mce-fragment=\"1\"\u003e Lynx Shunt VE.Can - A positive busbar with a space for a main system fuse and a negative busbar with a shunt for battery monitoring. It has VE.Can communication for monitoring and setup with a GX device\u003c\/li\u003e\n\u003cli class=\"intro\" data-mce-fragment=\"1\"\u003e. Lynx Smart BMS - For use together with Victron Energy Smart Lithium batteries. It contains a positive busbar with a contactor that is driven by a battery management system (BMS) and a negative busbar with a shunt for battery monitoring. It has Bluetooth communication for monitoring and setup via the VictronConnect App and VE.Can communication for monitoring with a GX device and the VRM portal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"warning\" data-mce-fragment=\"1\"\u003eThis product must be installed by a qualified electrician\/technician. All installations must adhere to local wiring regulations and standards.\u003cbr\u003e\u003cbr\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Lynx_Power_In.pdf\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Lynx_Power_In.pdf\" target=\"_blank\"\u003eInstallation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/ISO9001-certificate-2018%20(2).pdf\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/ISO9001-certificate-2018%20(2).pdf\" target=\"_blank\"\u003eISO 9001\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":45322733748373,"sku":"VIC-LYNX-DIST-P-IN","price":2329.0,"currency_code":"ZAR","in_stock":true}]},{"product_id":"dual-terminal-stud-m8-linked-set-150a","title":"Dual Terminal Stud M8-linked set 150A","description":"\u003cp\u003e\u003cstrong\u003eDual Terminal Stud M8-linked set 150A – Reliable Power Connection for Battery Systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eDual Terminal Stud M8-linked set 150A (Part No: VIC-DUAL-STUD-M8)\u003c\/strong\u003e is designed to provide a robust and reliable connection for battery systems. This dual terminal stud set is perfect for high current applications, offering secure and efficient power distribution. The M8-linked studs are rated for 150A, making them suitable for various energy storage and battery fuse applications.\u003c\/p\u003e\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e150A Current Rating:\u003c\/strong\u003e Designed for high current applications, ensuring reliable power distribution in energy storage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eM8-Linked Studs:\u003c\/strong\u003e The M8-sized studs are linked to provide a secure connection point, offering durability and efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Application:\u003c\/strong\u003e Ideal for use in battery systems, energy storage setups, and other high-power installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Details:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart No:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVIC-DUAL-STUD-M8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStud Size:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery systems, energy storage, fuse holders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Fuse Holders:\u003c\/strong\u003e Provides a reliable connection for battery fuse holders in high-power systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy Storage Systems:\u003c\/strong\u003e Ideal for use in energy storage applications requiring a durable and high-current connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEnsure reliable power distribution in your energy storage system with the \u003cstrong\u003eDual Terminal Stud M8-linked set 150A\u003c\/strong\u003e. Its durable design and high current rating make it a dependable solution for your battery connections.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Datasheet-Busbar-150-A-EN.pdf\" target=\"_blank\"\u003eData Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/ISO9001-certificate-2018%20(2).pdf\" target=\"_blank\"\u003eISO 9001\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":45322734567573,"sku":"VIC-DUAL-STUD-M8","price":359.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/dual-terminal-stud-m8-en.webp?v=1724759576"},{"product_id":"busbar-to-connect-4-high-current-connections-250a-70v","title":"Busbar to connect 4 High current connections 250A\/ 70V","description":"\u003ch3\u003eBusbar to Connect 4 High Current Connections 250A\/70V - Reliable Power Distribution for Battery and DC Systems\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePart No:\u003c\/strong\u003e VIC-BUS-B-250A\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Storage Systems - Battery Fuse Holder\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Busbar for 4 high current connections (250A\/70V) is an essential component for distributing high current in battery and DC power systems. It provides efficient connections for batteries and DC equipment while ensuring safe and reliable operation. Each busbar comes with a removable protection cover to enhance safety and protect against accidental contact.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Current Distribution:\u003c\/strong\u003e Rated for 250A\/70V, providing stable power distribution for demanding applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 High Current Connections:\u003c\/strong\u003e Designed to support up to 4 high current connections, making it ideal for battery and DC equipment setups.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable Protection Cover:\u003c\/strong\u003e Enhances safety by preventing accidental contact with live connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Design:\u003c\/strong\u003e Built to withstand high current demands and ensure long-lasting performance in energy storage systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 High Current Connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Cover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemovable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVIC-BUS-B-250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eAvailable Models:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e150A\/70V\u003c\/strong\u003e - 6 High Current Connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e250A\/70V\u003c\/strong\u003e - 4 High Current Connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e600A\/70V\u003c\/strong\u003e - 8 High Current Connections and 8 Low Current Connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eInstallation and Usage:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThis busbar is designed for high current distribution and should be installed by a qualified electrician or technician. It is suitable for a wide range of applications, including battery systems, DC power distribution, and energy storage systems.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eImportant Notes:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure that the busbar is installed in accordance with local wiring regulations and safety standards.\u003c\/li\u003e\n\u003cli\u003eProper installation by a qualified technician is essential for safe and effective use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Busbar 250A\/70V is a reliable solution for high current power distribution in energy storage and battery systems, providing safe and efficient connections for DC equipment.\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Datasheet-Busbar_250A.pdf\" target=\"_blank\"\u003eData Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/ISO9001-certificate-2018%20(2).pdf\" target=\"_blank\"\u003eISO 9001\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Busbar-250-A-2P-with-6-or-12-screws-EN.pdf\" target=\"_blank\"\u003eUser Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":45322735124629,"sku":"VIC-BUS-B-250A","price":939.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/VBB125040010.jpg?v=1724663122"},{"product_id":"nh-fuse-link-160a-for-keto-00","title":"NH Fuse-link 160A for KETO-00","description":"\u003cdiv class=\"warning\" data-mce-fragment=\"1\"\u003e\n\u003cp\u003eThe NH Fuse-link 160A for KETO-00 is a high-performance DC protection component designed to ensure safe and reliable operation between the battery and inverter in energy storage systems. Specifically intended for use with the KETO-00 (Size 00) fuse holder, this fuse link provides robust protection against overcurrents, helping to safeguard critical components and maintain system integrity. Suitable for residential, commercial, and industrial applications, this fuse link is a vital part of your energy storage solution.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdeal for DC Protection:\u003c\/strong\u003e Offers reliable DC protection between the battery and inverter, preventing overcurrent damage and ensuring safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with KETO-00 Fuse Holder:\u003c\/strong\u003e Specifically designed for use with the KETO-00 (Size 00) fuse holder, ensuring a secure and effective connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated for 160A:\u003c\/strong\u003e Provides strong DC protection with a 160A rating, suitable for a wide range of energy storage and power management applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCritical Safety Component:\u003c\/strong\u003e Protects vital system components from electrical faults and overloads, maintaining safety and operational integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Requirements:\u003c\/strong\u003e Must be installed by a qualified electrician or technician in accordance with local wiring regulations and standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN5014907-160A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStorage Systems - Battery Fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKETO-00 (Size 00) fuse holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC protection between battery and inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Usage Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Must be installed by a qualified electrician or technician. Adherence to local wiring regulations and standards is required to ensure safety and proper operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsage:\u003c\/strong\u003e Ideal for use as a DC protection fuse link in energy storage systems, providing a crucial safety barrier between the battery and inverter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompliance and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e Meets industry standards for electrical safety and fuse design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Advisory:\u003c\/strong\u003e Proper installation by a qualified professional is essential to maintain compliance and ensure reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy Choose NH Fuse-link 160A for KETO-00:\u003c\/strong\u003e Offers a dependable and compatible solution for DC protection in energy storage systems, preventing overcurrent damage and ensuring the longevity of your battery and inverter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBenefits:\u003c\/strong\u003e Enhances safety, prolongs the life of critical components, and complies with local safety standards when installed correctly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_Gehausetechnik_Kapitel_Gesamt.pdf\" target=\"_blank\"\u003eBrochure Jean Muller Disconnector (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_SE_Kapitel_2_NH_Sicherungseinsaetze_Betriebsklasse-gG%20(2).pdf\" target=\"_blank\"\u003eBrochure Jean Muller fuse\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/ce_n_16_01_se-gl-gg_400v-500v-690v.pdf\" target=\"_blank\"\u003eCE Declaration of Conformity Jean Muller fuse\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Data%20sheet%20NH%20fuse-link%20500V%20combi%20indicator%20M1GL%20100.pdf\" target=\"_blank\"\u003eData Sheet NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/14810_ba_t030_nh_sicherungslasttrennschalter_groesse_00_aufbaumontage.pdf\" target=\"_blank\"\u003eInstallation Manual Keto 00\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-1.pdf\" target=\"_blank\"\u003eTechnical Data DC Application\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-5.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/JEAN%20M%C3%9CLLER%20HEER%20DC%20gG.pdf\" target=\"_blank\"\u003eTechnical Data Jean Muller DC Confirmation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Technical%20data%20and%20drawing%20NH%20fuse-links.pdf\" target=\"_blank\"\u003eTechnical Data NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":45322781491349,"sku":"N5014907-160A","price":69.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/jean_muller_keto_nh_fuse-link_125a_for_keto-00_alternergy_1_feb818c4-a717-45ec-b63a-fe317b3a3278.jpg?v=1726486026"},{"product_id":"nh-fuse-link-125a-for-keto-00","title":"NH Fuse-link 125A for KETO-00","description":"\u003cdiv class=\"warning\" data-mce-fragment=\"1\"\u003e\n\u003cp\u003eThe NH Fuse-link 125A for KETO-00 is an essential DC protection component designed to ensure safe and reliable operation between the battery and inverter in energy storage systems. This fuse link is specifically intended for use with the KETO-00 (Size 00) fuse holder, providing robust protection against overcurrents to safeguard critical components. Ideal for residential, commercial, and industrial applications, this fuse link helps maintain the integrity and longevity of your energy storage setup.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdeal for DC Protection:\u003c\/strong\u003e Provides reliable protection between the battery and inverter, preventing damage from overcurrent conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with KETO-00 Fuse Holder:\u003c\/strong\u003e Specifically designed for use with the KETO-00 (Size 00) fuse holder, ensuring a secure fit and effective performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated for 125A:\u003c\/strong\u003e Offers strong DC protection with a 125A rating, suitable for various energy storage and power management applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCritical Safety Component:\u003c\/strong\u003e Protects your battery and inverter from electrical faults and overloads, maintaining system safety and performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Requirements:\u003c\/strong\u003e Must be installed by a qualified electrician or technician in accordance with local wiring regulations and standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN5014607-125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStorage Systems - Battery Fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKETO-00 (Size 00) fuse holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC protection between battery and inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Usage Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Must be installed by a qualified electrician or technician. Adherence to local wiring regulations and standards is required to ensure safety and proper operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsage:\u003c\/strong\u003e Designed for use as a DC protection fuse link in energy storage systems, providing a critical safety barrier between the battery and inverter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompliance and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e Meets industry standards for electrical safety and fuse design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Advisory:\u003c\/strong\u003e Proper installation by a qualified professional is essential to maintain compliance and ensure reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy Choose NH Fuse-link 125A for KETO-00:\u003c\/strong\u003e Provides a reliable and compatible solution for DC protection in energy storage systems, preventing overcurrent damage and ensuring the longevity of your battery and inverter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBenefits:\u003c\/strong\u003e Enhances safety, prolongs the life of critical components, and complies with local safety standards when installed correctly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications(1).pdf\" target=\"_blank\"\u003eApplication Note Gleichstromzulassung (German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/NH%20fuse%20links%20gG%20500V%20and%20gG%20690V%20for%20DC%20applications.pdf\" target=\"_blank\"\u003eApplication Note Gleichstromzulassung2 (German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_Gehausetechnik_Kapitel_Gesamt.pdf\" target=\"_blank\"\u003eBrochure Jean Muller Disconnector (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_SE_Kapitel_2_NH_Sicherungseinsaetze_Betriebsklasse-gG%20(2).pdf\" target=\"_blank\"\u003eBrochure Jean Muller fuse\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/ce_n_16_01_se-gl-gg_400v-500v-690v.pdf\" target=\"_blank\"\u003eCE Declaration of Conformity Jean Muller fuse\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/N5014607.pdf\" target=\"_blank\"\u003eData Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/14810_ba_t030_nh_sicherungslasttrennschalter_groesse_00_aufbaumontage.pdf\" target=\"_blank\"\u003eInstallation Manual Keto 00\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-1.pdf\" target=\"_blank\"\u003eTechnical Data DC Application\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-5.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/JEAN%20M%C3%9CLLER%20HEER%20DC%20gG.pdf\" target=\"_blank\"\u003eTechnical Data Jean Muller DC Confirmation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Technical%20data%20and%20drawing%20NH%20fuse-links.pdf\" target=\"_blank\"\u003eTechnical Data NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":45322781524117,"sku":"N5014607-125A","price":89.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/jean_muller_keto_nh_fuse-link_125a_for_keto-00_alternergy_1.jpg?v=1726485656"},{"product_id":"nh-fuse-link-80a-for-keto-00","title":"NH Fuse-link 80A for KETO-00","description":"\u003cp\u003eThe NH Fuse-link 80A for KETO-00 is an essential component designed to provide reliable DC protection between the battery and inverter in energy storage systems. Specifically intended for use with the KETO-00 (Size 00) fuse holder, this fuse link offers dependable protection against overcurrents, safeguarding critical components of your energy storage setup. Suitable for residential, commercial, and industrial applications, this fuse link is crucial for maintaining the safety and efficiency of your energy system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdeal for DC Protection:\u003c\/strong\u003e Provides effective protection between the battery and inverter, preventing damage from overcurrent conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with KETO-00 Fuse Holder:\u003c\/strong\u003e Specifically designed for use with the KETO-00 (Size 00) fuse holder, ensuring a secure and efficient connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated for 80A:\u003c\/strong\u003e Offers robust protection with an 80A rating, suitable for various energy storage and power management applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCritical Safety Component:\u003c\/strong\u003e Protects essential system components from electrical faults and overloads, maintaining safety and operational integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Requirements:\u003c\/strong\u003e Must be installed by a qualified electrician or technician in accordance with local wiring regulations and standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN5014107-80A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStorage Systems - Battery Fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKETO-00 (Size 00) fuse holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC protection between battery and inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Usage Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Must be installed by a qualified electrician or technician. Compliance with local wiring regulations and standards is essential for safety and proper operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsage:\u003c\/strong\u003e Ideal for use as a DC protection fuse link in energy storage systems, providing a crucial safety barrier between the battery and inverter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompliance and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e Meets industry standards for electrical safety and fuse design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Advisory:\u003c\/strong\u003e Proper installation by a qualified professional is necessary to maintain compliance and ensure reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy Choose NH Fuse-link 80A for KETO-00:\u003c\/strong\u003e Offers a reliable and compatible solution for DC protection in energy storage systems, preventing overcurrent damage and ensuring the safety and longevity of your battery and inverter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBenefits:\u003c\/strong\u003e Enhances safety, prolongs the life of critical components, and complies with local safety standards when installed correctly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications(1).pdf\" target=\"_blank\"\u003eApplication Note Gleichstromzulassung (German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/NH%20fuse%20links%20gG%20500V%20and%20gG%20690V%20for%20DC%20applications.pdf\" target=\"_blank\"\u003eApplication Note Gleichstromzulassung2 (German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_Gehausetechnik_Kapitel_Gesamt.pdf\" target=\"_blank\"\u003eBrochure Jean Muller Disconnector (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_SE_Kapitel_2_NH_Sicherungseinsaetze_Betriebsklasse-gG%20(2).pdf\" target=\"_blank\"\u003eBrochure Jean Muller fuse\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/ce_n_16_01_se-gl-gg_400v-500v-690v.pdf\" target=\"_blank\"\u003eCE Declaration of Conformity Jean Muller fuse\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Data%20sheet%20NH%20fuse-link%20500V%20combi%20indicator%20M1GL%20100.pdf\" target=\"_blank\"\u003eData Sheet NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/14810_ba_t030_nh_sicherungslasttrennschalter_groesse_00_aufbaumontage.pdf\" target=\"_blank\"\u003eInstallation Manual Keto 00\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-1.pdf\" target=\"_blank\"\u003eTechnical Data DC Application\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-5.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/JEAN%20M%C3%9CLLER%20HEER%20DC%20gG.pdf\" target=\"_blank\"\u003eTechnical Data Jean Muller DC Confirmation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Technical%20data%20and%20drawing%20NH%20fuse-links.pdf\" target=\"_blank\"\u003eTechnical Data NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":45322781589653,"sku":"N5014107-80A","price":269.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/image-upscaled-2024-09-16T134328.794.jpg?v=1726487016"},{"product_id":"nh-fuse-link-40a-for-keto-00","title":"NH Fuse-link 40A for KETO-00","description":"\u003cp\u003eThe NH Fuse-link 40A for KETO-00 is an essential DC protection component designed to provide safe and reliable operation between the battery and inverter in energy storage systems. This fuse link is specifically designed for use with the KETO-00 (Size 00) fuse holder, offering dependable protection against overcurrents to safeguard your system’s critical components. Ideal for residential, commercial, and industrial applications, this fuse link is a key part of maintaining your energy storage system's safety and performance.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdeal for DC Protection:\u003c\/strong\u003e Provides reliable DC protection between the battery and inverter, preventing damage from overcurrent conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with KETO-00 Fuse Holder:\u003c\/strong\u003e Designed specifically for use with the KETO-00 (Size 00) fuse holder, ensuring a secure and effective connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated for 40A:\u003c\/strong\u003e Offers dependable protection with a 40A rating, suitable for a variety of energy storage and power management applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCritical Safety Component:\u003c\/strong\u003e Protects vital system components from electrical faults and overloads, maintaining safety and operational integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Requirements:\u003c\/strong\u003e Must be installed by a qualified electrician or technician in accordance with local wiring regulations and standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN5013407-40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStorage Systems - Battery Fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKETO-00 (Size 00) fuse holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC protection between battery and inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Usage Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Must be installed by a qualified electrician or technician. Compliance with local wiring regulations and standards is essential for safety and proper operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsage:\u003c\/strong\u003e Ideal for use as a DC protection fuse link in energy storage systems, providing a crucial safety barrier between the battery and inverter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompliance and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e Meets industry standards for electrical safety and fuse design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Advisory:\u003c\/strong\u003e Proper installation by a qualified professional is necessary to maintain compliance and ensure reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy Choose NH Fuse-link 40A for KETO-00:\u003c\/strong\u003e Offers a dependable and compatible solution for DC protection in energy storage systems, preventing overcurrent damage and ensuring the safety and longevity of your battery and inverter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBenefits:\u003c\/strong\u003e Enhances safety, prolongs the life of critical components, and complies with local safety standards when installed correctly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_Gehausetechnik_Kapitel_Gesamt.pdf\" target=\"_blank\"\u003eBrochure Jean Muller Disconnector (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_SE_Kapitel_2_NH_Sicherungseinsaetze_Betriebsklasse-gG%20(2).pdf\" target=\"_blank\"\u003eBrochure Jean Muller fuse\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/ce_n_16_01_se-gl-gg_400v-500v-690v.pdf\" target=\"_blank\"\u003eCE Declaration of Conformity Jean Muller fuse\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Data%20sheet%20NH%20fuse-link%20500V%20combi%20indicator%20M1GL%20100.pdf\" target=\"_blank\"\u003eData Sheet NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/14810_ba_t030_nh_sicherungslasttrennschalter_groesse_00_aufbaumontage.pdf\" target=\"_blank\"\u003eInstallation Manual Keto 00\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-1.pdf\" target=\"_blank\"\u003eTechnical Data DC Application\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-5.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/JEAN%20M%C3%9CLLER%20HEER%20DC%20gG.pdf\" target=\"_blank\"\u003eTechnical Data Jean Muller DC Confirmation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Technical%20data%20and%20drawing%20NH%20fuse-links.pdf\" target=\"_blank\"\u003eTechnical Data NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":45322781622421,"sku":"N5013407-40A","price":259.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/image-upscaled-2024-09-16T133732.515.jpg?v=1726486658"},{"product_id":"nh-fuse-link-400a-for-keto-3","title":"NH Fuse-link 400A for Keto 3","description":"\u003cp\u003eThe NH Fuse-link 400A for Keto 3 is a robust DC protection component designed to ensure the safe and reliable operation of energy storage systems. Specifically intended for use with the NH3 fuse holder, this fuse link provides high-capacity protection against overcurrents and electrical faults. With its high current rating and substantial breaking capacity, it is ideal for demanding residential, commercial, and industrial applications, ensuring the longevity and safety of critical components.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdeal for DC Protection:\u003c\/strong\u003e Offers dependable DC protection between the battery and inverter, preventing overcurrent damage and ensuring safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with NH3 Fuse Holder:\u003c\/strong\u003e Designed for use with the NH3 fuse holder, ensuring a secure fit and efficient performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated for 400A:\u003c\/strong\u003e Provides high-capacity DC protection with a 400A rating, suitable for various energy storage and power management applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Voltage Capacity:\u003c\/strong\u003e Rated for 500V, making it suitable for high-power systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Breaking Capacity:\u003c\/strong\u003e Can safely disconnect high fault currents up to 120 kA, ensuring maximum safety in case of an electrical fault.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCritical Safety Component:\u003c\/strong\u003e Protects essential system components from electrical faults and overloads, maintaining safety and operational integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Requirements:\u003c\/strong\u003e Must be installed by a qualified electrician or technician in accordance with local wiring regulations and standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN3016205-400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStorage Systems - Battery Fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNH3 fuse holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC protection between battery and inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Usage Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Should be installed by a qualified electrician or technician. Adherence to local wiring regulations and standards is essential for safety and proper function.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsage:\u003c\/strong\u003e Ideal for use as a high-capacity DC protection fuse link in energy storage systems, providing a crucial safety barrier between the battery and inverter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompliance and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e Meets industry standards for electrical safety and fuse design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Advisory:\u003c\/strong\u003e Proper installation by a qualified professional is necessary to maintain compliance and ensure reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy Choose NH Fuse-link 400A for Keto 3:\u003c\/strong\u003e Offers reliable, high-capacity protection for energy storage systems, preventing overcurrent damage and ensuring the safety and longevity of your battery and inverter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBenefits:\u003c\/strong\u003e Ensures enhanced safety, high breaking capacity, and compliance with local safety standards when installed correctly, thereby prolonging the life of critical components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_SE_Kapitel_2_NH_Sicherungseinsaetze_Betriebsklasse-gG.pdf\" target=\"_blank\"\u003eBrochure Jean Muller\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_Gehausetechnik_Kapitel_Gesamt.pdf\" target=\"_blank\"\u003eBrochure Jean Muller Disconnector (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/CE_N_gG_400-800V%20(2).pdf\" target=\"_blank\"\u003eCE Declaration of Conformity Jean Muller 400A fuse\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/400A%20data%20sheet.pdf\" target=\"_blank\"\u003eData Sheet Keto 3 Fuse\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/14849c_BA_T036_NH_Sicherungslasttrennschalter_Groesse_1_3_Aufbaumontage_1_2pol%20(2).pdf\" target=\"_blank\"\u003eInstallation Manual KETO-3\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-5.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/JEAN%20M%C3%9CLLER%20HEER%20DC%20gG.pdf\" target=\"_blank\"\u003eTechnical Data Jean Muller DC Confirmation\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":45322781819029,"sku":"N3016205-400A","price":1359.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/image-upscaled-2024-09-16T133519.833.jpg?v=1726486526"},{"product_id":"nh-fuse-link-250a-for-keto-1","title":"NH Fuse-link 250A for Keto 1","description":"\u003cp\u003eThe NH Fuse-link 250A for Keto 1 is a heavy-duty DC protection component designed to ensure safe and efficient operation between the battery and inverter in energy storage systems. Specifically engineered for use with the KETO-1 (Size 1) fuse holder, this fuse link provides robust protection against overcurrents, safeguarding critical components and enhancing system reliability. Ideal for residential, commercial, and industrial applications, this fuse link is essential for maintaining the safety and longevity of your energy storage setup.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdeal for DC Protection:\u003c\/strong\u003e Provides robust protection between the battery and inverter, preventing overcurrent damage and ensuring safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with KETO-1 Fuse Holder:\u003c\/strong\u003e Specifically designed for use with the KETO-1 (Size 1) fuse holder, ensuring a secure and effective connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated for 250A:\u003c\/strong\u003e Offers high-capacity DC protection with a 250A rating, suitable for demanding energy storage and power management applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCritical Safety Component:\u003c\/strong\u003e Protects vital system components from electrical faults and overloads, maintaining safety and operational integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Requirements:\u003c\/strong\u003e Must be installed by a qualified electrician or technician in accordance with local wiring regulations and standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN1015605-250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStorage Systems - Battery Fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKETO-1 (Size 1) fuse holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC protection between battery and inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Usage Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Must be installed by a qualified electrician or technician. Adherence to local wiring regulations and standards is required to ensure safety and proper operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsage:\u003c\/strong\u003e Designed for use as a DC protection fuse link in energy storage systems, providing a critical safety barrier between the battery and inverter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompliance and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e Meets industry standards for electrical safety and fuse design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Advisory:\u003c\/strong\u003e Proper installation by a qualified professional is essential to maintain compliance and ensure reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy Choose NH Fuse-link 250A for Keto 1:\u003c\/strong\u003e Offers dependable, high-capacity protection for energy storage systems, preventing overcurrent damage and ensuring the safety and longevity of your battery and inverter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBenefits:\u003c\/strong\u003e Enhances safety, prolongs the life of critical components, and complies with local safety standards when installed correctly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_Gehausetechnik_Kapitel_Gesamt.pdf\" target=\"_blank\"\u003eBrochure Jean Muller Disconnector (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_SE_Kapitel_2_NH_Sicherungseinsaetze_Betriebsklasse-gG%20(2).pdf\" target=\"_blank\"\u003eBrochure Jean Muller fuse\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/ce_n_16_01_se-gl-gg_400v-500v-690v.pdf\" target=\"_blank\"\u003eCE Declaration of Conformity Jean Muller fuse\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Jean%20Muller%20Data%20sheet%20.pdf\" target=\"_blank\"\u003eData Sheet Data sheet NHA\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Data%20sheet%20NH%20fuse-link%20500V%20combi%20indicator%20M1GL%20100.pdf\" target=\"_blank\"\u003eData Sheet NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/14849c_BA_T036_NH_Sicherungslasttrennschalter_Groesse_1_3_Aufbaumontage_1_2pol.pdf\" target=\"_blank\"\u003eInstallation Manual Keto-1\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-1.pdf\" target=\"_blank\"\u003eTechnical Data DC Application\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-5.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/JEAN%20M%C3%9CLLER%20HEER%20DC%20gG.pdf\" target=\"_blank\"\u003eTechnical Data Jean Muller DC Confirmation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Technical%20data%20and%20drawing%20NH%20fuse-links.pdf\" target=\"_blank\"\u003eTechnical Data NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":45322781884565,"sku":"N1015605-250A","price":519.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/image-upscaled-2024-09-16T132519.575_5261374e-9387-4dc7-bb3b-9b0f727dbb9a.jpg?v=1726486246"},{"product_id":"nh-fuse-link-200a-for-keto-1","title":"NH Fuse-link 200A for Keto 1","description":"\u003cp\u003eThe NH Fuse-link 200A for Keto 1 is a high-capacity DC protection component designed to ensure safe and reliable operation between the battery and inverter in energy storage systems. This fuse link is specifically intended for use with the KETO-1 (Size 1) fuse holder, offering robust protection against overcurrents to safeguard critical components of your energy storage setup. Suitable for residential, commercial, and industrial applications, this fuse link helps maintain the integrity and longevity of your energy storage system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdeal for DC Protection:\u003c\/strong\u003e Provides dependable DC protection between the battery and inverter, preventing damage from overcurrent conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with KETO-1 Fuse Holder:\u003c\/strong\u003e Designed specifically for use with the KETO-1 (Size 1) fuse holder, ensuring a secure fit and effective performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated for 200A:\u003c\/strong\u003e Offers robust DC protection with a 200A rating, suitable for various energy storage and power management applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCritical Safety Component:\u003c\/strong\u003e Protects vital system components from electrical faults and overloads, maintaining safety and operational integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Requirements:\u003c\/strong\u003e Must be installed by a qualified electrician or technician in accordance with local wiring regulations and standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN1015205-200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStorage Systems - Battery Fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKETO-1 (Size 1) fuse holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC protection between battery and inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Usage Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Should be installed by a qualified electrician or technician. Compliance with local wiring regulations and standards is essential for safety and proper function.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsage:\u003c\/strong\u003e Designed for use as a DC protection fuse link in energy storage systems, providing a critical safety barrier between the battery and inverter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompliance and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e Meets industry standards for electrical safety and fuse design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Advisory:\u003c\/strong\u003e Proper installation by a qualified professional is necessary to maintain compliance and ensure reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy Choose NH Fuse-link 200A for Keto 1:\u003c\/strong\u003e Offers dependable protection for energy storage systems, preventing overcurrent damage and ensuring the safety and longevity of your battery and inverter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBenefits:\u003c\/strong\u003e Enhances safety, prolongs the life of critical components, and complies with local safety standards when installed correctly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_Gehausetechnik_Kapitel_Gesamt.pdf\" target=\"_blank\"\u003eBrochure Jean Muller Disconnector (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_SE_Kapitel_2_NH_Sicherungseinsaetze_Betriebsklasse-gG%20(2).pdf\" target=\"_blank\"\u003eBrochure Jean Muller fuse\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/ce_n_16_01_se-gl-gg_400v-500v-690v.pdf\" target=\"_blank\"\u003eCE Declaration of Conformity Jean Muller fuse\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Data%20sheet%20NH%20fuse-link%20500V%20combi%20indicator%20M1GL%20200.pdf\" target=\"_blank\"\u003eData Sheet (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Data%20sheet%20NH%20fuse-link%20500V%20combi%20indicator%20M1GL%20100.pdf\" target=\"_blank\"\u003eData Sheet NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/14849c_BA_T036_NH_Sicherungslasttrennschalter_Groesse_1_3_Aufbaumontage_1_2pol.pdf\" target=\"_blank\"\u003eInstallation Manual Keto-1\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-1.pdf\" target=\"_blank\"\u003eTechnical Data DC Application\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-1.pdf\" target=\"_blank\"\u003eTechnical Data DC Application\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-5.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/JEAN%20M%C3%9CLLER%20HEER%20DC%20gG.pdf\" target=\"_blank\"\u003eTechnical Data Jean Muller DC Confirmation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Technical%20data%20and%20drawing%20NH%20fuse-links.pdf\" target=\"_blank\"\u003eTechnical Data NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":45322781950101,"sku":"N1015205-200A","price":509.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/image-upscaled-2024-09-16T132519.575_096a13d0-63b3-4a2e-b995-5ce0e214ffe5.jpg?v=1726486164"},{"product_id":"nh-fuse-link-160a-for-keto-1","title":"NH Fuse-link 160A for Keto 1","description":"\u003cp\u003eThe NH Fuse-link 160A for Keto 1 is a high-capacity DC protection component designed to ensure safe and reliable operation between the battery and inverter in energy storage systems. This fuse link is specifically intended for use with the KETO-1 (Size 1) fuse holder, providing robust protection against overcurrents to safeguard your system's critical components. Ideal for residential, commercial, and industrial applications, this fuse link helps maintain the integrity and longevity of your energy storage setup.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdeal for DC Protection:\u003c\/strong\u003e Provides reliable protection between the battery and inverter, preventing damage from overcurrent conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with KETO-1 Fuse Holder:\u003c\/strong\u003e Designed specifically for use with the KETO-1 (Size 1) fuse holder, ensuring a secure and efficient connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated for 160A:\u003c\/strong\u003e Offers strong DC protection with a 160A rating, suitable for a wide range of energy storage and power management applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCritical Safety Component:\u003c\/strong\u003e Protects vital system components from electrical faults and overloads, maintaining safety and operational integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Requirements:\u003c\/strong\u003e Must be installed by a qualified electrician or technician in accordance with local wiring regulations and standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN1014905-160A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStorage Systems - Battery Fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKETO-1 (Size 1) fuse holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC protection between battery and inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Usage Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Should be installed by a qualified electrician or technician. Compliance with local wiring regulations and standards is essential for safety and proper function.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsage:\u003c\/strong\u003e Designed for use as a DC protection fuse link in energy storage systems, providing a critical safety barrier between the battery and inverter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompliance and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e Meets industry standards for electrical safety and fuse design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Advisory:\u003c\/strong\u003e Proper installation by a qualified professional is necessary to maintain compliance and ensure reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy Choose NH Fuse-link 160A for Keto 1:\u003c\/strong\u003e Offers dependable protection for energy storage systems, preventing overcurrent damage and ensuring the safety and longevity of your battery and inverter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBenefits:\u003c\/strong\u003e Enhances safety, prolongs the life of critical components, and complies with local safety standards when installed correctly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_Gehausetechnik_Kapitel_Gesamt.pdf\" target=\"_blank\"\u003eBrochure Jean Muller Disconnector (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_SE_Kapitel_2_NH_Sicherungseinsaetze_Betriebsklasse-gG%20(2).pdf\" target=\"_blank\"\u003eBrochure Jean Muller fuse\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/ce_n_16_01_se-gl-gg_400v-500v-690v.pdf\" target=\"_blank\"\u003eCE Declaration of Conformity Jean Muller fuse\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Jean%20Muller%20Data%20sheet%20.pdf\" target=\"_blank\"\u003eData Sheet Data sheet NH\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Data%20sheet%20NH%20fuse-link%20500V%20combi%20indicator%20M1GL%20100.pdf\" target=\"_blank\"\u003eData Sheet NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/14849c_BA_T036_NH_Sicherungslasttrennschalter_Groesse_1_3_Aufbaumontage_1_2pol.pdf\" target=\"_blank\"\u003eInstallation Manual Keto-1\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-1.pdf\" target=\"_blank\"\u003eTechnical Data DC Application\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-5.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/JEAN%20M%C3%9CLLER%20HEER%20DC%20gG.pdf\" target=\"_blank\"\u003eTechnical Data Jean Muller DC Confirmation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Technical%20data%20and%20drawing%20NH%20fuse-links.pdf\" target=\"_blank\"\u003eTechnical Data NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":45322782015637,"sku":"N1014905-160A","price":99.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/image-upscaled-2024-09-16T132519.575.jpg?v=1726485925"},{"product_id":"nh-fuse-link-125a-for-keto-1","title":"NH Fuse-link 125A for Keto 1","description":"\u003cp\u003eThe NH Fuse-link 125A for Keto 1 is a crucial DC protection component designed to ensure safe operation between the battery and inverter in energy storage systems. This fuse link is compatible with the KETO-1 (Size 1) fuse holder and provides robust protection against overcurrents, helping to safeguard your energy system from potential damage. Suitable for residential, commercial, and industrial applications, this fuse link is an essential element for maintaining the reliability and longevity of your energy storage setup.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdeal for DC Protection:\u003c\/strong\u003e Provides reliable DC protection between the battery and inverter, preventing damage from overcurrent conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with KETO-1 Fuse Holder:\u003c\/strong\u003e Specifically designed for use with the KETO-1 (Size 1) fuse holder, ensuring a secure fit and efficient performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated for 125A:\u003c\/strong\u003e Offers strong protection with a 125A rating, suitable for a wide range of energy storage and power management applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCritical Safety Component:\u003c\/strong\u003e Protects vital system components from electrical faults and overloads, maintaining safety and operational integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Requirements:\u003c\/strong\u003e Must be installed by a qualified electrician or technician in accordance with local wiring regulations and standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN1014605-125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStorage Systems - Battery Fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKETO-1 (Size 1) fuse holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC protection between battery and inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Usage Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Should be installed by a qualified electrician or technician. Compliance with local wiring regulations and standards is essential for safety and proper function.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsage:\u003c\/strong\u003e Designed for use as a DC protection fuse link in energy storage systems, providing a critical safety barrier between the battery and inverter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompliance and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e Meets industry standards for electrical safety and fuse design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Advisory:\u003c\/strong\u003e Proper installation by a qualified professional is necessary to maintain compliance and ensure reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy Choose NH Fuse-link 125A for Keto 1:\u003c\/strong\u003e Offers dependable protection for energy storage systems, preventing overcurrent damage and ensuring the safety and longevity of your battery and inverter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBenefits:\u003c\/strong\u003e Enhances safety, prolongs the life of critical components, and meets local safety standards when installed correctly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_Gehausetechnik_Kapitel_Gesamt.pdf\" target=\"_blank\"\u003eBrochure Jean Muller Disconnector (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_SE_Kapitel_2_NH_Sicherungseinsaetze_Betriebsklasse-gG%20(2).pdf\" target=\"_blank\"\u003eBrochure Jean Muller fuse\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/ce_n_16_01_se-gl-gg_400v-500v-690v.pdf\" target=\"_blank\"\u003eCE Declaration of Conformity Jean Muller fuse\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/N1014605.pdf\" target=\"_blank\"\u003eData Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Jean%20Muller%20Data%20sheet%20.pdf\" target=\"_blank\"\u003eData Sheet Data sheet NH\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/14849c_BA_T036_NH_Sicherungslasttrennschalter_Groesse_1_3_Aufbaumontage_1_2pol.pdf\" target=\"_blank\"\u003eInstallation Manual Keto-1\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-1.pdf\" target=\"_blank\"\u003eTechnical Data DC Application\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-5.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/JEAN%20M%C3%9CLLER%20HEER%20DC%20gG.pdf\" target=\"_blank\"\u003eTechnical Data Jean Muller DC Confirmation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Technical%20data%20and%20drawing%20NH%20fuse-links.pdf\" target=\"_blank\"\u003eTechnical Data NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":45322782081173,"sku":"N1014605-125A","price":109.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/3502601264.jpg?v=1726485519"},{"product_id":"nh-fuse-link-100a-for-keto-1","title":"NH Fuse-link 100A for Keto 1","description":"\u003cdiv data-mce-fragment=\"1\" class=\"warning\"\u003e\n\u003cp\u003eThe NH Fuse-link 100A for Keto 1 is a reliable and efficient DC protection component designed for use between batteries and inverters in energy storage systems. This fuse link is specifically intended to be used with the KETO-1 (Size 1) fuse holder, providing essential protection against overcurrents and ensuring the safe operation of your electrical system. Ideal for residential, commercial, and industrial applications, this fuse link helps safeguard critical components and extend the life of your energy storage setup.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdeal for DC Protection:\u003c\/strong\u003e Designed to provide reliable DC protection between the battery and inverter, preventing overcurrent damage and ensuring safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with KETO-1 Fuse Holder:\u003c\/strong\u003e Specifically designed for use with the KETO-1 (Size 1) fuse holder, ensuring a secure and efficient connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated for 100A:\u003c\/strong\u003e Provides robust protection with a rating of 100A, suitable for various energy storage and power management applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential Safety Component:\u003c\/strong\u003e Helps protect your battery and inverter from potential damage caused by electrical faults or overloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Requirements:\u003c\/strong\u003e Must be installed by a qualified electrician or technician in accordance with local wiring regulations and standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN1014305-100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStorage Systems - Battery Fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKETO-1 (Size 1) fuse holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC protection between battery and inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Usage Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Must be installed by a qualified electrician or technician. Adhere to local wiring regulations and standards to ensure safety and proper operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsage:\u003c\/strong\u003e Ideal for use as a DC protection fuse link in energy storage systems, providing a crucial safety barrier between the battery and inverter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompliance and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e Meets industry standards for electrical safety and fuse design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Advisory:\u003c\/strong\u003e Proper installation by a qualified professional is required to maintain compliance and ensure reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy Choose NH Fuse-link 100A for Keto 1:\u003c\/strong\u003e Offers a dependable and compatible solution for DC protection in energy storage systems, safeguarding your battery and inverter from overcurrent damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBenefits:\u003c\/strong\u003e Ensures safe operation, extends the lifespan of critical components, and complies with local safety standards when installed correctly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_Gehausetechnik_Kapitel_Gesamt.pdf\" target=\"_blank\"\u003eBrochure Jean Muller Disconnector (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_SE_Kapitel_2_NH_Sicherungseinsaetze_Betriebsklasse-gG%20(2).pdf\" target=\"_blank\"\u003eBrochure Jean Muller fuse\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/ce_n_16_01_se-gl-gg_400v-500v-690v.pdf\" target=\"_blank\"\u003eCE Declaration of Conformity Jean Muller fuse\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Data%20sheet%20NH%20fuse-link%20500V%20combi%20indicator%20M1GL%20100.pdf\" target=\"_blank\"\u003eData Sheet NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/14849c_BA_T036_NH_Sicherungslasttrennschalter_Groesse_1_3_Aufbaumontage_1_2pol.pdf\" target=\"_blank\"\u003eInstallation Manual Keto-1\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-1.pdf\" target=\"_blank\"\u003eTechnical Data DC Application\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-5.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/JEAN%20M%C3%9CLLER%20HEER%20DC%20gG.pdf\" target=\"_blank\"\u003eTechnical Data Jean Muller DC Confirmation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Technical%20data%20and%20drawing%20NH%20fuse-links.pdf\" target=\"_blank\"\u003eTechnical Data NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/div\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":45322782179477,"sku":"N1014305-100A","price":369.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/N1014305-100A.png?v=1726485304"},{"product_id":"nh-fuse-link-80a-for-keto-1","title":"NH Fuse-link 80A for Keto 1","description":"\u003cdiv data-mce-fragment=\"1\" class=\"warning\"\u003e\n\u003cp\u003eThe NH Fuse-link 80A for Keto 1 is an essential DC protection component designed to ensure safe and reliable operation between the battery and inverter in energy storage systems. This fuse link is specifically designed for use with the KETO-1 (Size 1) fuse holder, providing reliable protection against overcurrents to safeguard critical system components. Ideal for residential, commercial, and industrial applications, this fuse link helps maintain the safety and longevity of your energy storage setup.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdeal for DC Protection:\u003c\/strong\u003e Provides dependable DC protection between the battery and inverter, preventing damage from overcurrent conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with KETO-1 Fuse Holder:\u003c\/strong\u003e Specifically designed for use with the KETO-1 (Size 1) fuse holder, ensuring a secure and effective connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated for 80A:\u003c\/strong\u003e Offers reliable protection with an 80A rating, suitable for a variety of energy storage and power management applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCritical Safety Component:\u003c\/strong\u003e Protects vital system components from electrical faults and overloads, maintaining safety and operational integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Requirements:\u003c\/strong\u003e Must be installed by a qualified electrician or technician in accordance with local wiring regulations and standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN1014105-80A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStorage Systems - Battery Fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKETO-1 (Size 1) fuse holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC protection between battery and inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Usage Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Must be installed by a qualified electrician or technician. Adherence to local wiring regulations and standards is required to ensure safety and proper operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsage:\u003c\/strong\u003e Ideal for use as a DC protection fuse link in energy storage systems, providing a crucial safety barrier between the battery and inverter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompliance and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e Meets industry standards for electrical safety and fuse design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Advisory:\u003c\/strong\u003e Proper installation by a qualified professional is essential to maintain compliance and ensure reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy Choose NH Fuse-link 80A for Keto 1:\u003c\/strong\u003e Offers a dependable and compatible solution for DC protection in energy storage systems, preventing overcurrent damage and ensuring the safety and longevity of your battery and inverter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBenefits:\u003c\/strong\u003e Enhances safety, prolongs the life of critical components, and complies with local safety standards when installed correctly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_Gehausetechnik_Kapitel_Gesamt.pdf\" target=\"_blank\"\u003eBrochure Jean Muller Disconnector (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_SE_Kapitel_2_NH_Sicherungseinsaetze_Betriebsklasse-gG%20(2).pdf\" target=\"_blank\"\u003eBrochure Jean Muller fuse\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/ce_n_16_01_se-gl-gg_400v-500v-690v.pdf\" target=\"_blank\"\u003eCE Declaration of Conformity Jean Muller fuse\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Data%20sheet%20NH%20fuse-link%20500V%20combi%20indicator%20M1GL%2080.pdf\" target=\"_blank\"\u003eData Sheet (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Data%20sheet%20NH%20fuse-link%20500V%20combi%20indicator%20M1GL%20100.pdf\" target=\"_blank\"\u003eData Sheet NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/14849c_BA_T036_NH_Sicherungslasttrennschalter_Groesse_1_3_Aufbaumontage_1_2pol.pdf\" target=\"_blank\"\u003eInstallation Manual Keto-1\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-1.pdf\" target=\"_blank\"\u003eTechnical Data DC Application\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-5.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/JEAN%20M%C3%9CLLER%20HEER%20DC%20gG.pdf\" target=\"_blank\"\u003eTechnical Data Jean Muller DC Confirmation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Technical%20data%20and%20drawing%20NH%20fuse-links.pdf\" target=\"_blank\"\u003eTechnical Data NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":45322782245013,"sku":"N1014105-80A","price":129.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/N1014305-100A_715e5afc-7535-499b-8e1b-3f25d2389ec9.png?v=1726486782"},{"product_id":"keto-3-battery-disconnector-with-400a-fuses","title":"KETO 3 Battery Disconnector with 400A Fuses","description":"\u003cp\u003e\u003cstrong\u003eProduct Title:\u003c\/strong\u003e KETO-3 Battery Disconnector with 400A Fuses - High-Capacity Battery Isolation Solution\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntroduction:\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong\u003eKETO-3 Battery Disconnector with 400A Fuses\u003c\/strong\u003e offers a robust and reliable solution for battery disconnection in high-demand power management systems. This package includes a Jean Muller KETO size 3 fuse-switch-disconnector body and two 400A NH Fuse-Links, ensuring maximum safety and effective performance. Part of the trusted KETO range from Jean Müller, this disconnector is known for its precision engineering and commitment to user safety, making it a top choice for secure battery isolation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Capacity Battery Disconnection:\u003c\/strong\u003e Features a Jean Muller KETO size 3 disconnector and two 400A NH Fuse-Links, providing reliable and secure isolation for battery systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Electrical Capacity:\u003c\/strong\u003e Supports a maximum DC current of 400A and a DC voltage rating of 250V, ideal for heavy-duty applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Adaptable Design:\u003c\/strong\u003e With an overall width of 182mm, the KETO-3 disconnector is compact enough for versatile installation options while maintaining a strong and stable presence.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Terminals:\u003c\/strong\u003e Equipped with M10 lugs that accommodate cable sizes from 25 to 150mm², ensuring secure and flexible connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mountable:\u003c\/strong\u003e Designed for easy installation on standard DIN rails, providing a stable and secure mounting solution.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eKETO-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Type\u003c\/td\u003e\n\u003ctd\u003eNH Fuse-Link 400A (2 included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum DC Current\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Width\u003c\/td\u003e\n\u003ctd\u003e182 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminals\u003c\/td\u003e\n\u003ctd\u003eM10 lugs, cable area 25-150mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003eDIN Rail Mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Jean Muller KETO-3 Fuse-Switch-Disconnector Body (Battery Isolator)\u003c\/li\u003e\n\u003cli\u003e2 x NH Fuse-Link 400A for KETO-3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation and Usage Information:\u003c\/strong\u003e\u003cbr\u003eThis product must be installed by a qualified electrician or technician. All installations must adhere to local wiring regulations and standards. To install, mount the KETO-3 Battery Disconnector on a standard DIN rail and connect it using M10 lugs with cables sized between 25-150mm². Ensure the two 400A NH Fuse-Links are properly placed for optimal battery disconnection. For detailed installation and safety guidelines, refer to the provided brochures, data sheets, and manuals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance and Warranty:\u003c\/strong\u003e\u003cbr\u003eThe KETO-3 Battery Disconnector complies with all relevant industry standards for safety and performance in solar and battery storage systems. Detailed compliance information and warranty details are available in the brochures and technical data sheets provided in English and German.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy Choose This Product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Safety and Reliability:\u003c\/strong\u003e Provides robust isolation for battery systems with high current demands, ensuring secure operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Performance:\u003c\/strong\u003e Supports high current and voltage ratings, making it suitable for the most demanding applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Installation:\u003c\/strong\u003e Easily integrates with various cable sizes and mounts securely on DIN rails.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrusted Quality:\u003c\/strong\u003e Part of the Jean Muller KETO range, known for its superior engineering and focus on user safety.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_Gehausetechnik_Kapitel_Gesamt.pdf\" target=\"_blank\"\u003eBrochure Jean Muller Disconnector (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-1.pdf\" target=\"_blank\"\u003eTechnical Data DC Application\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-5.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/JEAN%20M%C3%9CLLER%20HEER%20DC%20gG.pdf\" target=\"_blank\"\u003eTechnical Data Jean Muller DC Confirmation\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":45322782277781,"sku":"KETO-3-400A","price":4349.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/image-upscaled_42_-Copy_869ea138-5823-4047-a084-5be6479a2181.jpg?v=1725439357"},{"product_id":"jean-muller-fuse-switch-disconnector-keto-size-3-body-battery-isolator","title":"Jean Muller Fuse-switch-disconnector KETO size 3 body (battery isolator)","description":"\u003cdiv class=\"warning\" data-mce-fragment=\"1\"\u003e\n\u003ch3\u003eJean Muller Fuse-Switch Disconnector KETO Size 3 Body (Battery Isolator)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePart No:\u003c\/strong\u003e KETO-3\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Storage Systems - Battery Fuse Holder\u003c\/p\u003e\n\u003cp\u003eEnhance your battery disconnection with the \u003cstrong\u003eKeto Size 3 Fuse-Switch Disconnector\u003c\/strong\u003e from Jean Müller, renowned for their precision and user safety focus. Designed to provide robust DC protection between batteries and inverters, this fuse holder supports 315A and 400A fuse links.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum DC Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Voltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e182mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM10 lugs with cable area from 25-150mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e315A and 400A fuse links\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Disconnection:\u003c\/strong\u003e Provides secure and reliable disconnection between battery and inverter for enhanced safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Capacity:\u003c\/strong\u003e Supports up to 630A DC current, ideal for large-scale and high-demand applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Mounting:\u003c\/strong\u003e DIN rail mountable for easy integration into various electrical setups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Requirement:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThis product must be installed by a qualified electrician or technician. Ensure all installations comply with local wiring regulations and standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Note:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe use of KETO switches ensures safe and secure battery isolation, providing peace of mind in demanding solar or energy storage installations.\u003c\/p\u003e\n\u003cp\u003eEquip your system with the Jean Muller KETO Size 3 Fuse-Switch Disconnector to ensure maximum safety and reliability in all conditions.\u003c\/p\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_Gehausetechnik_Kapitel_Gesamt.pdf\" target=\"_blank\"\u003eBrochure Jean Muller Disconnector (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/CE_T_KETO.pdf\" target=\"_blank\"\u003eCE Declaration of Conformity Keto 3 Jean Muller (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Data%20Sheet.pdf\" target=\"_blank\"\u003eData Sheet Keto 3\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/14849c_BA_T036_NH_Sicherungslasttrennschalter_Groesse_1_3_Aufbaumontage_1_2pol.pdf\" target=\"_blank\"\u003eInstallation Manual KETO-3\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-5.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_Gehausetechnik_Kapitel_Gesamt.pdf\" target=\"_blank\"\u003eBrochure Jean Muller Disconnector (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/CE_T_KETO.pdf\" target=\"_blank\"\u003eCE Declaration of Conformity Keto 3 Jean Muller (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Data%20Sheet.pdf\" target=\"_blank\"\u003eData Sheet Keto 3\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/14849c_BA_T036_NH_Sicherungslasttrennschalter_Groesse_1_3_Aufbaumontage_1_2pol.pdf\" target=\"_blank\"\u003eInstallation Manual KETO-3\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-5.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":45322782408853,"sku":"KETO-3","price":1679.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/image-upscaled_42_601b139a-491a-42e1-8ee2-e4bb37685572.jpg?v=1725364757"},{"product_id":"keto-1-battery-disconnector-with-250a-fuses","title":"KETO 1 Battery Disconnector with 250A Fuses","description":"\u003cdiv class=\"prod_composite\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"compositeHeading\" data-mce-fragment=\"1\"\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Title:\u003c\/strong\u003e KETO-1 Battery Disconnector with 250A Fuses - Robust Battery Isolation Solution\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntroduction:\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong\u003eKETO-1 Battery Disconnector with 250A Fuses\u003c\/strong\u003e offers a reliable and secure solution for battery disconnection in various power management systems. This product includes a Jean Muller KETO size 1 fuse-switch-disconnector body and two 250A NH Fuse-Links, ensuring maximum safety and performance. The KETO range from Jean Müller is renowned for its attention to detail and dedication to user safety, making it a trusted choice for battery isolation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecure Battery Disconnection:\u003c\/strong\u003e Equipped with a Jean Muller KETO size 1 disconnector and two 250A NH Fuse-Links to ensure robust and reliable isolation in battery systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Electrical Capacity:\u003c\/strong\u003e Supports a maximum DC current of 250A and a DC voltage rating of 250V, suitable for demanding power management applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Easy to Install:\u003c\/strong\u003e Features an overall width of 184mm and a system size of 300mm, facilitating easy integration into existing setups.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Terminals:\u003c\/strong\u003e Comes with M10 lugs that accommodate cable areas ranging from 25 to 150mm², providing flexible and secure connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mountable:\u003c\/strong\u003e Easily mountable on standard DIN rails for straightforward and secure installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eKETO-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Type\u003c\/td\u003e\n\u003ctd\u003eNH Fuse-Link 250A (2 included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum DC Current\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Width\u003c\/td\u003e\n\u003ctd\u003e184 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Size\u003c\/td\u003e\n\u003ctd\u003e300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminals\u003c\/td\u003e\n\u003ctd\u003eM10 lugs, cable area 25-150mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003eDIN Rail Mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Jean Muller KETO-1 Fuse-Switch-Disconnector Body (Battery Isolator)\u003c\/li\u003e\n\u003cli\u003e2 x NH Fuse-Link 250A for KETO-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation and Usage Information:\u003c\/strong\u003e\u003cbr\u003eThis product must be installed by a qualified electrician or technician. Ensure all installations comply with local wiring regulations and standards. Mount the KETO-1 Battery Disconnector on a standard DIN rail, connect the terminals using M10 lugs with appropriate cable sizes (25-150mm²), and correctly place the two included 250A NH Fuse-Links. Detailed instructions and safety guidelines are provided in the product documentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance and Warranty:\u003c\/strong\u003e\u003cbr\u003eThe KETO-1 Battery Disconnector meets industry standards for safety and performance in solar and storage system installations. For further information on compliance and warranty, please refer to the brochures, data sheets, and installation manuals available in English and German.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy Choose This Product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Safety and Reliability:\u003c\/strong\u003e Provides robust battery isolation, ensuring safe operation in power management systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Performance:\u003c\/strong\u003e Supports high current and voltage ratings, ideal for demanding applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible and Versatile Installation:\u003c\/strong\u003e Compatible with various cable sizes and easily mountable on DIN rails.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrusted Quality:\u003c\/strong\u003e Part of the Jean Muller KETO range, known for its focus on user safety and reliable performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_Gehausetechnik_Kapitel_Gesamt.pdf\" target=\"_blank\"\u003eBrochure Jean Muller Disconnector (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Technical%20data%20NH%20Fuseswitch%20Disconnector%20KETO-1-2%20F.pdf\" target=\"_blank\"\u003eData Sheet Keto 1 (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Data%20sheet%20NH%20fuse-link%20500V%20combi%20indicator%20M1GL%20100.pdf\" target=\"_blank\"\u003eData Sheet NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/14810_ba_t030_nh_sicherungslasttrennschalter_groesse_00_aufbaumontage.pdf\" target=\"_blank\"\u003eInstallation Manual Keto 00\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-5.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Technical%20data%20and%20drawing%20NH%20fuse-links.pdf\" target=\"_blank\"\u003eTechnical Data NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"TextSummary\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"warning\" data-mce-fragment=\"1\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":45322782507157,"sku":"KETO-1-250A","price":1859.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/image-upscaled_42_-Copy_e7e22b16-9090-4600-aa48-30ed0b07320e.jpg?v=1725439170"},{"product_id":"keto-1-battery-disconnector-with-200a-fuses","title":"KETO 1 Battery Disconnector with 200A Fuses","description":"\u003cp\u003e\u003cstrong\u003eProduct Title:\u003c\/strong\u003e KETO 1 Battery Disconnector with 200A Fuses - Secure Battery Isolation Solution\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntroduction:\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong\u003eKETO 1 Battery Disconnector\u003c\/strong\u003e (Part No: KETO-1-200A) offers a robust and secure solution for battery disconnection in various storage systems. Featuring a Jean Muller KETO size 1 fuse-switch-disconnector body and two 200A NH Fuse-Links, this product is designed to provide maximum safety and reliable performance. Known for their meticulous attention to user safety, the KETO range from Jean Müller ensures peace of mind for all battery management applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Battery Disconnection:\u003c\/strong\u003e Provides a secure isolation solution with a Jean Muller KETO size 1 disconnector and two 200A NH Fuse-Links, enhancing safety in battery systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Current and Voltage Capacity:\u003c\/strong\u003e Supports a maximum DC current of 250A and a DC voltage rating of 250V, suitable for various storage and power management applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Versatile Design:\u003c\/strong\u003e Features an overall width of 184mm and a system size of 300mm, allowing easy integration into existing setups.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Connection Points:\u003c\/strong\u003e Comes with M10 lugs that accommodate cable areas ranging from 25 to 150mm², providing robust and flexible connectivity options.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Mounting:\u003c\/strong\u003e DIN rail mountable for straightforward installation and secure placement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eKETO-1-200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Type\u003c\/td\u003e\n\u003ctd\u003eNH Fuse-Link 200A (2 included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum DC Current\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Width\u003c\/td\u003e\n\u003ctd\u003e184 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Size\u003c\/td\u003e\n\u003ctd\u003e300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminals\u003c\/td\u003e\n\u003ctd\u003eM10 lugs, cable area 25-150mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003eDIN Rail Mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Jean Muller KETO-1 Fuse-Switch-Disconnector Body (Battery Isolator)\u003c\/li\u003e\n\u003cli\u003e2 x NH Fuse-Link 200A for KETO-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation and Usage Information:\u003c\/strong\u003e\u003cbr\u003eTo install the KETO 1 Battery Disconnector, mount it on a standard DIN rail and connect it to the battery system using M10 lugs with cables sized between 25-150mm². Ensure the included 200A NH Fuse-Links are properly placed to guarantee safe and reliable battery disconnection. For detailed installation and safety guidelines, refer to the provided product documentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance and Warranty:\u003c\/strong\u003e\u003cbr\u003eThis battery disconnector complies with industry standards for safety and performance. For further details on compliance and warranty, please consult the product documentation or the manufacturer's website.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy Choose This Product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Safety:\u003c\/strong\u003e Provides a robust solution for battery disconnection with a focus on user safety and reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Performance:\u003c\/strong\u003e Supports high current and voltage ratings, making it ideal for demanding storage system applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile and Easy to Install:\u003c\/strong\u003e Compatible with various cable sizes and easily mountable on DIN rails.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Package:\u003c\/strong\u003e Includes all necessary components for a secure and effective battery isolation solution.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_Gehausetechnik_Kapitel_Gesamt.pdf\" target=\"_blank\"\u003eBrochure Jean Muller Disconnector (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Technical%20data%20NH%20Fuseswitch%20Disconnector%20KETO-1-2%20F.pdf\" target=\"_blank\"\u003eData Sheet Keto 1 (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Data%20sheet%20NH%20fuse-link%20500V%20combi%20indicator%20M1GL%20100.pdf\" target=\"_blank\"\u003eData Sheet NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/14810_ba_t030_nh_sicherungslasttrennschalter_groesse_00_aufbaumontage.pdf\" target=\"_blank\"\u003eInstallation Manual Keto 00\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-5.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Technical%20data%20and%20drawing%20NH%20fuse-links.pdf\" target=\"_blank\"\u003eTechnical Data NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":45322782539925,"sku":"KETO-1-200A","price":1839.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/image-upscaled_42_-Copy_306d9dcf-3468-4262-8749-079f5f51ef1e.jpg?v=1725439060"},{"product_id":"keto-1-battery-disconnector-with-160a-fuses","title":"KETO 1 Battery Disconnector with 160A Fuses","description":"\u003cp\u003e\u003cstrong\u003eProduct Title:\u003c\/strong\u003e KETO-1 Jean Muller Fuse-Switch-Disconnector with 160A NH Fuse-Link - Battery Isolator\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntroduction:\u003c\/strong\u003e\u003cbr\u003eEnhance the safety and reliability of your battery disconnection system with the \u003cstrong\u003eKETO-1 Jean Muller Fuse-Switch-Disconnector\u003c\/strong\u003e. Renowned for its robust design and focus on user safety, the KETO range from Jean Müller offers secure and dependable battery isolation solutions. This package includes the KETO size 1 body and two 160A NH Fuse-Links, providing a comprehensive solution for battery management in various applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust and Secure Battery Disconnection:\u003c\/strong\u003e Designed for reliable battery isolation with the KETO range, ensuring maximum safety and performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Current and Voltage Ratings:\u003c\/strong\u003e Supports a maximum DC current of 250A and a DC voltage rating of 250V, suitable for a wide range of applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Versatile Design:\u003c\/strong\u003e Overall width of 184mm and system size of 300mm, making it easy to integrate into existing setups.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Terminals:\u003c\/strong\u003e Equipped with M10 lugs compatible with cable areas ranging from 25 to 150mm², offering flexibility and robust connectivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mountable:\u003c\/strong\u003e Easily mountable on standard DIN rails for convenient installation and secure placement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eKETO-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Type\u003c\/td\u003e\n\u003ctd\u003eNH Fuse-Link 160A (2 included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum DC Current\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Width\u003c\/td\u003e\n\u003ctd\u003e184 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Size\u003c\/td\u003e\n\u003ctd\u003e300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminals\u003c\/td\u003e\n\u003ctd\u003eM10 lugs, cable area 25-150mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003eDIN Rail Mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Jean Muller KETO-1 Fuse-Switch-Disconnector Body (Battery Isolator)\u003c\/li\u003e\n\u003cli\u003e2 x NH Fuse-Link 160A for KETO-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation and Usage Information:\u003c\/strong\u003e\u003cbr\u003eInstall the KETO-1 Jean Muller Fuse-Switch-Disconnector on a standard DIN rail, connecting the terminals using M10 lugs with the appropriate cable size (25-150mm²). Ensure the correct placement of the two included 160A NH Fuse-Links for proper battery isolation. For detailed instructions and safety information, refer to the provided brochures, data sheets, and installation manuals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance and Warranty:\u003c\/strong\u003e\u003cbr\u003eThis product meets all relevant safety and performance standards. For further information on compliance and warranty, please consult the product brochures and data sheets available in English and German.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy Choose This Product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Safety and Reliability:\u003c\/strong\u003e Offers a robust solution for battery disconnection with a focus on user safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Integration:\u003c\/strong\u003e Compatible with various cable sizes and mountable on DIN rails for easy installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Performance:\u003c\/strong\u003e Supports high current and voltage ratings, making it suitable for demanding applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Package:\u003c\/strong\u003e Includes all necessary components for a complete and secure battery isolation solution.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_Gehausetechnik_Kapitel_Gesamt.pdf\" target=\"_blank\"\u003eBrochure Jean Muller Disconnector (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Technical%20data%20NH%20Fuseswitch%20Disconnector%20KETO-1-2%20F.pdf\" target=\"_blank\"\u003eData Sheet Keto 1 (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Data%20sheet%20NH%20fuse-link%20500V%20combi%20indicator%20M1GL%20100.pdf\" target=\"_blank\"\u003eData Sheet NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/14810_ba_t030_nh_sicherungslasttrennschalter_groesse_00_aufbaumontage.pdf\" target=\"_blank\"\u003eInstallation Manual Keto 00\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-5.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Technical%20data%20and%20drawing%20NH%20fuse-links.pdf\" target=\"_blank\"\u003eTechnical Data NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":45322782605461,"sku":"KETO-1-160A","price":1039.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/image-upscaled_42_-Copy.jpg?v=1725438922"},{"product_id":"jean-muller-fuse-switch-disconnector-keto-size-1-body-battery-isolator","title":"Jean Muller Fuse-switch-disconnector KETO size 1 body (battery isolator)","description":"\u003cdiv class=\"warning\" data-mce-fragment=\"1\"\u003e\n\u003ch3\u003eJean Muller NH1 Battery Fuse Disconnector – Robust DC Protection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eJean Muller NH1 Battery Fuse Disconnector\u003c\/strong\u003e is a reliable and secure solution for DC protection between batteries and inverters. Designed to support fuse ratings up to 250A, this fuse holder ensures safe and efficient operation by allowing you to select the appropriate fuse link (Amps) based on your application requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor Transition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransitioning from blue to black (both versions may be delivered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupplier Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT100112002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMust be installed by a qualified electrician\/technician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdheres to local wiring regulations and standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust DC Protection:\u003c\/strong\u003e Ideal for ensuring safety between battery and inverter connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Application:\u003c\/strong\u003e Compatible with various fuse ratings up to 250A, offering flexibility in different electrical setups.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Safety:\u003c\/strong\u003e Choose the correct fuse link to match your specific application needs, maintaining optimal performance and protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e During the transition period, the NH1 Battery Fuse Disconnector will be available in both blue and black versions. Moving forward, all KETO switches will be black. Please ensure your order complies with your system's color preferences or requirements.\u003c\/p\u003e\n\u003ch3\u003eWhy Choose the Jean Muller NH1 Battery Fuse Disconnector?\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eJean Muller NH1 Fuse Disconnector\u003c\/strong\u003e provides an ideal combination of safety, reliability, and flexibility, making it a perfect choice for professionals looking to protect DC systems effectively. Its ability to handle various fuse ratings ensures it can meet the needs of diverse electrical setups while maintaining strict adherence to safety standards.\u003c\/p\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_Gehausetechnik_Kapitel_Gesamt.pdf\" target=\"_blank\"\u003eBrochure Jean Muller Disconnector (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/CE_T_KETO..pdf\" target=\"_blank\"\u003eCE Declaration of Conformity\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Technical%20data%20NH%20Fuseswitch%20Disconnector%20KETO-1-2%20F.pdf\" target=\"_blank\"\u003eData Sheet Keto 1 (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Data%20sheet%20NH%20fuse-link%20500V%20combi%20indicator%20M1GL%20100.pdf\" target=\"_blank\"\u003eData Sheet NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/14849c_BA_T036_NH_Sicherungslasttrennschalter_Groesse_1_3_Aufbaumontage_1_2pol.pdf\" target=\"_blank\"\u003eInstallation Manual Keto-1\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-5.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Technical%20data%20and%20drawing%20NH%20fuse-links.pdf\" target=\"_blank\"\u003eTechnical Data NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/div\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":45322782670997,"sku":"KETO-1","price":849.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/image-upscaled_42.jpg?v=1725364356"},{"product_id":"keto-battery-disconnector-with-80a-fuses","title":"KETO Battery Disconnector with 80A Fuses","description":"\u003cp\u003e\u003cstrong\u003eProduct Title:\u003c\/strong\u003e KETO-00 Battery Disconnector with 80A Fuses - Reliable Battery Isolation Solution\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntroduction:\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong\u003eKETO-00 Battery Disconnector with 80A Fuses\u003c\/strong\u003e is a secure and efficient solution for battery disconnection in various power management systems. This package includes a Jean Muller KETO size 00 fuse-switch-disconnector body and two 80A NH Fuse-Links, providing dependable safety and performance. Renowned for its precision engineering and commitment to user safety, the KETO range from Jean Müller is the ideal choice for robust battery isolation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDependable Battery Disconnection:\u003c\/strong\u003e Features a Jean Muller KETO size 00 disconnector with two 80A NH Fuse-Links for secure and effective battery isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMedium Current Capacity:\u003c\/strong\u003e Supports a maximum DC current of 80A and a DC voltage rating of 250V, suitable for a wide range of applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design for Space-Saving:\u003c\/strong\u003e With an overall width of 106mm and a system size of 195mm, the KETO-00 disconnector is ideal for installations where space is limited.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Connection Options:\u003c\/strong\u003e Equipped with M8 lugs compatible with cable sizes from 25 to 95mm², ensuring flexible and secure connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mountable:\u003c\/strong\u003e Easily mountable on standard DIN rails for quick and secure installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eKETO-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Type\u003c\/td\u003e\n\u003ctd\u003eNH Fuse-Link 80A (2 included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum DC Current\u003c\/td\u003e\n\u003ctd\u003e80A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Width\u003c\/td\u003e\n\u003ctd\u003e106 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Size\u003c\/td\u003e\n\u003ctd\u003e195 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminals\u003c\/td\u003e\n\u003ctd\u003eM8 lugs, cable area 25-95mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003eDIN Rail Mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Jean Muller KETO-00 Fuse-Switch-Disconnector Body (Battery Isolator)\u003c\/li\u003e\n\u003cli\u003e2 x NH Fuse-Link 80A for KETO-00\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation and Usage Information:\u003c\/strong\u003e\u003cbr\u003eThis product must be installed by a qualified electrician or technician, and all installations must adhere to local wiring regulations and standards. Mount the KETO-00 Battery Disconnector on a standard DIN rail and connect using M8 lugs with cables sized between 25-95mm². Ensure the two included 80A NH Fuse-Links are correctly positioned for optimal battery disconnection. For detailed installation instructions, refer to the provided brochures, data sheets, and manuals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance and Warranty:\u003c\/strong\u003e\u003cbr\u003eThe KETO-00 Battery Disconnector complies with all relevant industry standards for safety and performance in battery storage systems. For further details on compliance and warranty, refer to the brochures, data sheets, and technical documents available in English and German.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy Choose This Product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecure and Effective:\u003c\/strong\u003e Provides reliable battery disconnection, ensuring safety and performance in various applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Space-Saving:\u003c\/strong\u003e Ideal for installations with limited space due to its compact design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Installation:\u003c\/strong\u003e Compatible with a range of cable sizes and easily mountable on DIN rails.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProven Quality:\u003c\/strong\u003e Part of the Jean Muller KETO range, known for its superior engineering and dedication to user safety.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_Gehausetechnik_Kapitel_Gesamt.pdf\" target=\"_blank\"\u003eBrochure Jean Muller Disconnector (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Data%20sheet%20NH%20fuse-link%20500V%20combi%20indicator%20M1GL%20100.pdf\" target=\"_blank\"\u003eData Sheet NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/14810_ba_t030_nh_sicherungslasttrennschalter_groesse_00_aufbaumontage.pdf\" target=\"_blank\"\u003eInstallation Manual Keto 00\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-1.pdf\" target=\"_blank\"\u003eTechnical Data DC Application\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-5.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/JEAN%20M%C3%9CLLER%20HEER%20DC%20gG.pdf\" target=\"_blank\"\u003eTechnical Data Jean Muller DC Confirmation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Technical%20data%20and%20drawing%20NH%20fuse-links.pdf\" target=\"_blank\"\u003eTechnical Data NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/t0588_keto-00-3-aufbautrenner.pdf\" target=\"_blank\"\u003eWhite Paper Drawing KETO 00\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":45322782736533,"sku":"KETO-00-80A","price":879.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/image-upscaled_41_377462a0-8f6f-4939-b9d5-8a82e939d82c.jpg?v=1725440116"},{"product_id":"keto-battery-disconnector-with-40a-fuses","title":"KETO Battery Disconnector with 40A Fuses","description":"\u003cp\u003e\u003cstrong\u003eProduct Title:\u003c\/strong\u003e KETO-00 Battery Disconnector with 40A Fuses - Compact and Reliable Battery Isolation Solution\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntroduction:\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong\u003eKETO-00 Battery Disconnector with 40A Fuses\u003c\/strong\u003e provides a secure and effective solution for battery disconnection in various low to medium-power applications. This package includes a Jean Muller KETO size 00 fuse-switch-disconnector body and two 40A NH Fuse-Links, ensuring reliable performance and safety. The KETO range from Jean Müller is known for its high-quality engineering and attention to detail, making it an ideal choice for safe battery management.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Battery Disconnection:\u003c\/strong\u003e Includes a Jean Muller KETO size 00 disconnector and two 40A NH Fuse-Links to ensure secure battery isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow to Medium Current Capacity:\u003c\/strong\u003e Supports a maximum DC current of 40A and a DC voltage rating of 250V, suitable for various low to medium-power applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e With an overall width of 106mm and a system size of 195mm, the KETO-00 disconnector is ideal for installations where space is limited.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Terminals:\u003c\/strong\u003e Equipped with M8 lugs compatible with cable sizes ranging from 25 to 95mm², ensuring flexible and secure connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mountable:\u003c\/strong\u003e Easily mountable on standard DIN rails for quick and secure installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eKETO-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Type\u003c\/td\u003e\n\u003ctd\u003eNH Fuse-Link 40A (2 included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum DC Current\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Width\u003c\/td\u003e\n\u003ctd\u003e106 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Size\u003c\/td\u003e\n\u003ctd\u003e195 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminals\u003c\/td\u003e\n\u003ctd\u003eM8 lugs, cable area 25-95mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003eDIN Rail Mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Jean Muller KETO-00 Fuse-Switch-Disconnector Body (Battery Isolator)\u003c\/li\u003e\n\u003cli\u003e2 x NH Fuse-Link 40A for KETO-00\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation and Usage Information:\u003c\/strong\u003e\u003cbr\u003eThis product must be installed by a qualified electrician or technician, adhering to local wiring regulations and standards. Mount the KETO-00 Battery Disconnector on a standard DIN rail and connect it using M8 lugs with cables sized between 25-95mm². Ensure the two included 40A NH Fuse-Links are correctly placed to achieve optimal battery disconnection. For detailed installation and safety guidelines, refer to the provided brochures, data sheets, and manuals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance and Warranty:\u003c\/strong\u003e\u003cbr\u003eThe KETO-00 Battery Disconnector complies with all relevant industry standards for safety and performance in battery storage systems. Further details on compliance and warranty can be found in the brochures, data sheets, and technical documents available in English and German.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy Choose This Product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecure and Effective:\u003c\/strong\u003e Provides a reliable solution for low to medium-power battery disconnection, ensuring safety and performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Space-Saving:\u003c\/strong\u003e Ideal for installations with limited space due to its compact design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Installation:\u003c\/strong\u003e Compatible with various cable sizes and easily mountable on DIN rails.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProven Quality:\u003c\/strong\u003e Part of the Jean Muller KETO range, known for its precision engineering and dedication to user safety.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_Gehausetechnik_Kapitel_Gesamt.pdf\" target=\"_blank\"\u003eBrochure Jean Muller Disconnector (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Data%20sheet%20NH%20fuse-link%20500V%20combi%20indicator%20M1GL%20100.pdf\" target=\"_blank\"\u003eData Sheet NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/14810_ba_t030_nh_sicherungslasttrennschalter_groesse_00_aufbaumontage.pdf\" target=\"_blank\"\u003eInstallation Manual Keto 00\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-1.pdf\" target=\"_blank\"\u003eTechnical Data DC Application\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-5.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/JEAN%20M%C3%9CLLER%20HEER%20DC%20gG.pdf\" target=\"_blank\"\u003eTechnical Data Jean Muller DC Confirmation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Technical%20data%20and%20drawing%20NH%20fuse-links.pdf\" target=\"_blank\"\u003eTechnical Data NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/t0588_keto-00-3-aufbautrenner.pdf\" target=\"_blank\"\u003eWhite Paper Drawing KETO 00\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":45322782802069,"sku":"KETO-00-40A","price":859.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/image-upscaled_41_b1579a0b-7b6b-4984-b5b8-9c8e53356ecc.jpg?v=1725439915"},{"product_id":"keto-battery-disconnector-with-160a-fuses","title":"KETO Battery Disconnector with 160A Fuses","description":"\u003cp\u003e\u003cstrong\u003eProduct Title:\u003c\/strong\u003e KETO-00 Battery Disconnector with 160A Fuses - Compact and Secure Battery Isolation Solution\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntroduction:\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong\u003eKETO-00 Battery Disconnector with 160A Fuses\u003c\/strong\u003e provides a robust and reliable solution for battery disconnection in various power management systems. This package includes a Jean Muller KETO size 00 fuse-switch-disconnector body and two 160A NH Fuse-Links, ensuring secure and effective battery isolation. Renowned for their commitment to user safety, the KETO range from Jean Müller offers exceptional engineering quality and reliable performance for safe battery management.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEffective Battery Disconnection:\u003c\/strong\u003e Equipped with a Jean Muller KETO size 00 disconnector and two 160A NH Fuse-Links for reliable battery isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Electrical Capacity:\u003c\/strong\u003e Supports a maximum DC current of 160A and a DC voltage rating of 250V, suitable for various applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Space-Saving Design:\u003c\/strong\u003e Features an overall width of 106mm and a system size of 195mm, making it ideal for installations where space is limited.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Terminals:\u003c\/strong\u003e Includes M8 lugs compatible with cable sizes from 25 to 95mm², ensuring secure and flexible connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mountable:\u003c\/strong\u003e Easily mountable on standard DIN rails for straightforward installation and secure placement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eKETO-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Type\u003c\/td\u003e\n\u003ctd\u003eNH Fuse-Link 160A (2 included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum DC Current\u003c\/td\u003e\n\u003ctd\u003e160A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Width\u003c\/td\u003e\n\u003ctd\u003e106 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Size\u003c\/td\u003e\n\u003ctd\u003e195 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminals\u003c\/td\u003e\n\u003ctd\u003eM8 lugs, cable area 25-95mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003eDIN Rail Mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Jean Muller KETO-00 Fuse-Switch-Disconnector Body (Battery Isolator)\u003c\/li\u003e\n\u003cli\u003e2 x NH Fuse-Link 160A for KETO-00\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation and Usage Information:\u003c\/strong\u003e\u003cbr\u003eThis product must be installed by a qualified electrician or technician, adhering to local wiring regulations and standards. To install, mount the KETO-00 Battery Disconnector on a standard DIN rail and connect using M8 lugs with cables sized between 25-95mm². Ensure that the two included 160A NH Fuse-Links are correctly positioned for optimal battery disconnection. Detailed installation instructions are provided in the product brochures, data sheets, and manuals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance and Warranty:\u003c\/strong\u003e\u003cbr\u003eThe KETO-00 Battery Disconnector complies with all relevant industry standards for safety and performance in solar and battery storage systems. Refer to the brochures, data sheets, and technical documents available in English and German for further details on compliance and warranty.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy Choose This Product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable and Secure:\u003c\/strong\u003e Provides effective battery disconnection with a focus on safety and performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Versatile:\u003c\/strong\u003e Space-saving design suitable for installations with limited space requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible and Easy to Install:\u003c\/strong\u003e Compatible with various cable sizes and easily mountable on DIN rails.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProven Quality:\u003c\/strong\u003e Part of the Jean Muller KETO range, known for its precision engineering and commitment to user safety.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_Gehausetechnik_Kapitel_Gesamt.pdf\" target=\"_blank\"\u003eBrochure Jean Muller Disconnector (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Data%20sheet%20NH%20fuse-link%20500V%20combi%20indicator%20M1GL%20100.pdf\" target=\"_blank\"\u003eData Sheet NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/14810_ba_t030_nh_sicherungslasttrennschalter_groesse_00_aufbaumontage.pdf\" target=\"_blank\"\u003eInstallation Manual Keto 00\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-1.pdf\" target=\"_blank\"\u003eTechnical Data DC Application\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-5.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/JEAN%20M%C3%9CLLER%20HEER%20DC%20gG.pdf\" target=\"_blank\"\u003eTechnical Data Jean Muller DC Confirmation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Technical%20data%20and%20drawing%20NH%20fuse-links.pdf\" target=\"_blank\"\u003eTechnical Data NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/t0588_keto-00-3-aufbautrenner.pdf\" target=\"_blank\"\u003eWhite Paper Drawing KETO 00\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":45322782834837,"sku":"KETO-00-160A","price":479.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/image-upscaled_41_1eb13aae-7548-4574-a9da-5db9a432345d.jpg?v=1725439752"},{"product_id":"keto-battery-disconnector-with-125a-fuses","title":"KETO Battery Disconnector with 125A Fuses","description":"\u003cdiv class=\"prod_composite\" data-mce-fragment=\"1\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"TextSummary\" data-mce-fragment=\"1\"\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Title:\u003c\/strong\u003e KETO-00 Battery Disconnector with 125A Fuses - Compact Battery Isolation Solution\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntroduction:\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong\u003eKETO-00 Battery Disconnector with 125A Fuses\u003c\/strong\u003e is a compact and reliable solution for secure battery disconnection in various power management systems. This package includes a Jean Muller KETO size 00 fuse-switch-disconnector body and two 125A NH Fuse-Links, providing robust protection and safety. The KETO range from Jean Müller is recognized for its attention to detail and commitment to user safety, making it a trusted choice for battery isolation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Secure Battery Disconnection:\u003c\/strong\u003e Features a Jean Muller KETO size 00 disconnector with two 125A NH Fuse-Links for effective and reliable battery isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdeal for Low to Medium Current Applications:\u003c\/strong\u003e Supports a maximum DC current of 125A and a DC voltage rating of 250V, suitable for various storage and power systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpace-Saving Design:\u003c\/strong\u003e With an overall width of 106mm and a system size of 195mm, the KETO-00 disconnector is ideal for installations where space is limited.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Terminals:\u003c\/strong\u003e Comes with M8 lugs compatible with cable areas ranging from 25 to 95mm², ensuring secure and flexible connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mountable:\u003c\/strong\u003e Easily mountable on standard DIN rails for convenient and secure installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eKETO-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Type\u003c\/td\u003e\n\u003ctd\u003eNH Fuse-Link 125A (2 included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum DC Current\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Width\u003c\/td\u003e\n\u003ctd\u003e106 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Size\u003c\/td\u003e\n\u003ctd\u003e195 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminals\u003c\/td\u003e\n\u003ctd\u003eM8 lugs, cable area 25-95mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003eDIN Rail Mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Jean Muller KETO-00 Fuse-Switch-Disconnector Body (Battery Isolator)\u003c\/li\u003e\n\u003cli\u003e2 x NH Fuse-Link 125A for KETO-00\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation and Usage Information:\u003c\/strong\u003e\u003cbr\u003eThis product must be installed by a qualified electrician or technician, with adherence to local wiring regulations and standards. Mount the KETO-00 Battery Disconnector on a standard DIN rail and connect using M8 lugs with cables sized between 25-95mm². Properly place the two included 125A NH Fuse-Links for optimal battery disconnection. Refer to the provided brochures, data sheets, and installation manuals for detailed guidelines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance and Warranty:\u003c\/strong\u003e\u003cbr\u003eThe KETO-00 Battery Disconnector complies with all relevant industry standards for safety and performance in solar and battery storage systems. For further details on compliance and warranty, refer to the brochures, data sheets, and technical documents available in English and German.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy Choose This Product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Safety:\u003c\/strong\u003e Provides secure and effective battery disconnection with a focus on user safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Efficient:\u003c\/strong\u003e Space-saving design is perfect for installations with limited space requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile and Easy to Install:\u003c\/strong\u003e Compatible with various cable sizes and easily mountable on DIN rails.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrusted Quality:\u003c\/strong\u003e Part of the Jean Muller KETO range, known for its superior engineering and user safety.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_Gehausetechnik_Kapitel_Gesamt.pdf\" target=\"_blank\"\u003eBrochure Jean Muller Disconnector (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Data%20sheet%20NH%20fuse-link%20500V%20combi%20indicator%20M1GL%20100.pdf\" target=\"_blank\"\u003eData Sheet NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/14810_ba_t030_nh_sicherungslasttrennschalter_groesse_00_aufbaumontage.pdf\" target=\"_blank\"\u003eInstallation Manual Keto 00\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-1.pdf\" target=\"_blank\"\u003eTechnical Data DC Application\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-5.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/JEAN%20M%C3%9CLLER%20HEER%20DC%20gG.pdf\" target=\"_blank\"\u003eTechnical Data Jean Muller DC Confirmation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Technical%20data%20and%20drawing%20NH%20fuse-links.pdf\" target=\"_blank\"\u003eTechnical Data NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/t0588_keto-00-3-aufbautrenner.pdf\" target=\"_blank\"\u003eWhite Paper Drawing KETO 00\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":45322782867605,"sku":"KETO-00-125A","price":509.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/image-upscaled_41_152ae802-02bf-4106-9a88-33db5a812b73.jpg?v=1725439661"},{"product_id":"jean-muller-fuse-switch-disconnector-keto-size-00-body-battery-isolator","title":"Jean Muller Fuse-switch-disconnector KETO size 00 body (battery isolator)","description":"\u003cdiv class=\"warning\" data-mce-fragment=\"1\"\u003e\n\u003ch3\u003eKeto Size 00 Battery Disconnect Switch – Secure and Reliable Battery Disconnection\u003c\/h3\u003e\n\u003cp\u003eEnhance the safety and performance of your battery system with the \u003cstrong\u003eKeto Size 00 Battery Disconnect Switch\u003c\/strong\u003e from Jean Müller, renowned for its high-quality standards and meticulous attention to detail. Designed to ensure maximum user safety, this switch provides robust and secure battery disconnection for various applications.\u003c\/p\u003e\n\u003ch4\u003eKey Features:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum DC Current:\u003c\/strong\u003e 160A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Voltage Rating:\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Width:\u003c\/strong\u003e 106mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Size:\u003c\/strong\u003e 195mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminals:\u003c\/strong\u003e M8 lugs compatible with cables from 25mm² to 95mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall Mountable:\u003c\/strong\u003e Easy and secure installation on various surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Compatibility:\u003c\/strong\u003e Requires two fuses sized according to the maximum battery current with an added safety factor for enhanced protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAdditional Information:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor Change:\u003c\/strong\u003e KETO switches will transition to a \u003cstrong\u003eblack color\u003c\/strong\u003e; during the transition period, both blue and black versions may be delivered. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupplier Code:\u003c\/strong\u003e T500113002\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInstallation Requirements:\u003c\/h4\u003e\n\u003cp\u003eThis product must be installed by a \u003cstrong\u003equalified electrician or technician\u003c\/strong\u003e. Ensure all installations comply with local wiring regulations and standards to maintain the integrity and safety of your battery system.\u003c\/p\u003e\n\u003ch4\u003eWhy Choose the Keto Size 00 Battery Disconnect Switch?\u003c\/h4\u003e\n\u003cp\u003eThe Keto Size 00 switch from Jean Müller offers robust and reliable protection for your battery systems, designed to handle up to \u003cstrong\u003e160A\u003c\/strong\u003e of DC current with a \u003cstrong\u003e250V DC voltage rating\u003c\/strong\u003e. Its compatibility with a wide range of cables, secure mounting options, and adherence to safety standards make it an ideal choice for ensuring safe and efficient battery disconnection in residential, commercial, or industrial applications.\u003c\/p\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Katalog_Gehausetechnik_Kapitel_Gesamt.pdf\" target=\"_blank\"\u003eBrochure Jean Muller Disconnector (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/CE_T_KETO.pdf\" target=\"_blank\"\u003eCE Declaration of Conformity\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Data%20sheet%20NH%20fuse-link%20500V%20combi%20indicator%20M1GL%20100.pdf\" target=\"_blank\"\u003eData Sheet NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/14810_ba_t030_nh_sicherungslasttrennschalter_groesse_00_aufbaumontage.pdf\" target=\"_blank\"\u003eInstallation Manual Keto 00\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/TI-N001_DC-Anwendungen_DC-Applications-5.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Technical%20data%20and%20drawing%20NH%20fuse-links.pdf\" target=\"_blank\"\u003eTechnical Data NH Fuse Link (English, German)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/t0588_keto-00-3-aufbautrenner.pdf\" target=\"_blank\"\u003eWhite Paper Drawing KETO 00\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":45322782965909,"sku":"KETO-00","price":349.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/image-upscaled_41.jpg?v=1725363739"},{"product_id":"aptsa-400a-fuse-link-for-keto-2","title":"APTSA 400A fuse link for KETO 2","description":"\u003cdiv class=\"warning\" data-mce-fragment=\"1\"\u003e\n\u003ch3\u003eAPTSA 400A Fuse Link for KETO 2 - High-Capacity Overcurrent Protection for 15kW and 16kW Low Voltage Inverters\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePart No:\u003c\/strong\u003e NHG2B-FUSE-400A\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Storage Systems - Battery Fuses\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe APTSA 400A Fuse Link is engineered for heavy-duty overcurrent protection in inverter-battery systems, particularly suited for 15kW and 16kW low voltage (48V) inverters. This fuse ensures the safety of energy storage systems by preventing damage caused by excessive currents. It is compatible with the KETO 2 fuse holder and is built to handle the demands of large-scale energy storage applications.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e400A Overcurrent Protection:\u003c\/strong\u003e Provides robust circuit protection for large inverter-battery systems, ensuring operational safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Voltage Application:\u003c\/strong\u003e Designed for use with 15kW and 16kW low voltage (48V) inverters, offering high-capacity protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurability:\u003c\/strong\u003e Constructed to meet industrial standards, ensuring reliable performance under demanding conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand Availability:\u003c\/strong\u003e Primarily Eaton Bussmann, with Mersen offered as an alternative due to stock variability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Usage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15kW and 16kW Low Voltage (48V) Inverters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Holder Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKETO 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEaton Bussmann (or Mersen)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQualified electrician\/technician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eInstallation and Usage:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe APTSA 400A Fuse Link is ideal for protecting high-capacity inverter-battery systems in both commercial and industrial applications. Ensure that the fuse rating matches the system’s specifications for effective protection. Proper installation by a qualified technician is essential to meet safety standards and maintain system integrity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Notes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure compatibility with your system's voltage and current ratings before selecting the fuse link.\u003c\/li\u003e\n\u003cli\u003eInstallation must comply with local electrical codes and safety regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"warning\" data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/01_00003492.pdf\" target=\"_blank\"\u003eCE Declaration of Conformity Eaton\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Eaton-400NHG2B-400-NH%20FUSE%20400A%20400V%20GG-GL%20SIZE%202-en_GB.pdf\" target=\"_blank\"\u003eData Sheet Eaton bussman\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/bus-ele-an-10507-hsf.pdf\" target=\"_blank\"\u003eInstallation Manual Eaton bussmann fuse selection guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/DC%20Rating.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"Advanced Product Technology","offers":[{"title":"Default Title","offer_id":45322818715797,"sku":"NHG2B-FUSE-400A","price":159.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/NHG2B-FUSE-400A.jpg?v=1724402401"},{"product_id":"aptsa-315a-fuse-link-for-keto-2","title":"APTSA 315A fuse link for KETO 2","description":"\u003cdiv class=\"warning\" data-mce-fragment=\"1\"\u003e\n\u003ch3\u003eAPTSA 315A Fuse Link for KETO 2 - Industrial-Grade Overcurrent Protection for Inverter-Battery Systems\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePart No:\u003c\/strong\u003e NHG2B-FUSE-315A\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Storage Systems - Battery Fuses\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe APTSA 315A Fuse Link is a high-capacity safety component designed to protect inverter-battery systems from overcurrent scenarios. This fuse is recommended for use in 12kW low voltage (48V) inverters, providing reliable and efficient circuit protection. Its compatibility with the KETO 2 fuse holder ensures secure and stable performance in demanding energy storage applications.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e315A Overcurrent Protection:\u003c\/strong\u003e Prevents damage to inverter-battery systems by interrupting electrical flow when current exceeds safe levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Voltage Application:\u003c\/strong\u003e Suitable for 12kW low voltage (48V) inverters, ensuring optimized protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Design:\u003c\/strong\u003e Built for industrial environments, ensuring reliability and longevity in harsh conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable Brand Availability:\u003c\/strong\u003e Primarily Eaton Bussmann, with Mersen as an alternative brand depending on availability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e315A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Usage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12kW Low Voltage (48V) Inverters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Holder Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKETO 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEaton Bussmann (or Mersen)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQualified electrician\/technician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eInstallation and Usage:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe APTSA 315A fuse link provides essential overcurrent protection for high-capacity low voltage inverter systems. Ensure that the fuse rating matches the system's operating limits for optimal protection. Installation should be performed by a qualified technician to comply with local wiring regulations and maintain system safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Notes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify compatibility with your inverter and battery specifications before installation.\u003c\/li\u003e\n\u003cli\u003eAlways follow local electrical codes and standards to ensure a safe and reliable installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"warning\" data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/01_00003492.pdf\" target=\"_blank\"\u003eCE Declaration of Conformity Eaton Bussmann\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Eaton-315NHG2B-690-NH%20FUSE%20315A%20690V%20gG%20SIZE%202-en_GB.pdf\" target=\"_blank\"\u003eData Sheet Eaton bussmann.\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/bus-ele-an-10507-hsf.pdf\" target=\"_blank\"\u003eInstallation Manual Eaton bussmann fuse selection guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/DC%20Rating.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"Advanced Product Technology","offers":[{"title":"Default Title","offer_id":45322818748565,"sku":"NHG2B-FUSE-315A","price":149.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/Eaton-315NHG2B.jpg?v=1724402093"},{"product_id":"aptsa-battery-disconnector-with-400a-fuses","title":"APTSA Battery Disconnector with 400A Fuses","description":"\u003cdiv class=\"prod_composite\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"compositeHeading\" data-mce-fragment=\"1\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"TextSummary\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"warning\" data-mce-fragment=\"1\"\u003e\n\u003ch3\u003eAPTSA Battery Disconnector with 400A Fuses - Secure Battery Isolation for High-Capacity Systems\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePart No:\u003c\/strong\u003e NHG2B-400A\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Storage Systems - Battery Fuse Holder\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe APTSA Battery Disconnector with 400A fuses is an essential component for high-capacity battery storage systems, providing overcurrent protection and secure disconnection. This kit includes the KETO size 2 body and two 400A fuse links, ensuring optimal safety and performance for demanding energy storage applications.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Capacity Protection:\u003c\/strong\u003e Equipped with 400A fuse links, this disconnector is designed to protect large inverter-battery systems from overcurrent, ensuring safety during high-demand operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Battery Isolation:\u003c\/strong\u003e The KETO size 2 disconnector allows for reliable battery isolation during system maintenance or emergency situations, ensuring complete safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Made from high-quality materials, both the disconnector body and fuse links are built for durability and long-term performance in industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Sourcing of Components:\u003c\/strong\u003e Primarily Eaton Bussmann fuse links are supplied; however, Mersen fuses may be provided due to stock availability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisconnector Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNH2 (Size 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum DC Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM10 lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Area Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25-150mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded Components\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKETO Size 2 Body, 2 x 400A Fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Link Brand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEaton Bussmann \/ Mersen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQualified electrician\/technician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eInstallation and Usage:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThis APTSA Battery Disconnector with 400A fuses is designed to provide secure and reliable battery disconnection in high-power systems. With robust overcurrent protection, it ensures safety during the operation of large-scale energy storage solutions. It is compatible with NH2 fuse holders and supports a wide range of industrial battery installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Notes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure that the 400A fuse rating aligns with the specific requirements of your inverter-battery system.\u003c\/li\u003e\n\u003cli\u003eProfessional installation by a qualified technician is required to guarantee proper operation and safety compliance.\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Eaton-200NHG1B-NH%20FUSE%20200A%20500V%20GG-GL%20SIZE%201-en_GB.pdf\" target=\"_blank\"\u003eData Sheet 200A Eaton Bussmann Fuse Link For Keto 1\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Advanced Product Technology","offers":[{"title":"Default Title","offer_id":45322818781333,"sku":"NHG2B-400A","price":2389.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/ebh1o3tmv-eaton-moeller-disconnector-bt-250-a-ac-690-v-nh1-ac23b-3p-iec_16265f59-c62a-4127-9b3e-cd4fde4c950d.jpg?v=1724404449"},{"product_id":"aptsa-battery-disconnector-with-315a-fuses","title":"APTSA Battery Disconnector with 315A Fuses","description":"\u003cdiv class=\"prod_composite\" data-mce-fragment=\"1\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"TextSummary\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"warning\" data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\n\u003ch3\u003eAPTSA Battery Disconnector with 315A Fuses - Secure Battery Isolation and Protection for High-Capacity Systems\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePart No:\u003c\/strong\u003e NHG2B-315A\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Storage Systems - Battery Fuse Holder\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe APTSA Battery Disconnector with 315A fuses is engineered for high-capacity battery storage systems, offering robust overcurrent protection and secure disconnection. This assembly includes the KETO size 2 battery isolator and two 315A fuse links, providing reliable protection and operational safety in demanding energy storage applications.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Capacity Protection:\u003c\/strong\u003e Equipped with 315A fuse links, this disconnector provides protection for large inverter-battery systems, ensuring system safety during high-current operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Isolation:\u003c\/strong\u003e The KETO size 2 disconnector allows for easy and secure battery isolation during system maintenance or emergencies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Built for reliability, the disconnector and fuse links are made from high-quality materials to withstand the rigors of industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Component Sourcing:\u003c\/strong\u003e Fuse links are primarily sourced from Eaton Bussmann, with Mersen as an alternative due to stock availability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e315A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisconnector Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNH2 (Size 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum DC Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e315A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM10 lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Area Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25-150mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded Components\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKETO Size 2 Body, 2 x 315A Fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Link Brand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEaton Bussmann \/ Mersen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQualified electrician\/technician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eInstallation and Usage:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eDesigned for high-current battery systems, the APTSA Battery Disconnector with 315A fuses is essential for secure and efficient battery management. Its reliable fuse-switch-disconnector body and 315A fuse links ensure safe disconnection and protection from overcurrent risks. Compatible with NH2 fuse holders, it supports a wide range of industrial energy storage systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Notes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the 315A fuse rating is suitable for your specific inverter-battery setup.\u003c\/li\u003e\n\u003cli\u003eThis product must be installed by a qualified technician to ensure proper safety and functionality.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/DC%20Rating.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Advanced Product Technology","offers":[{"title":"Default Title","offer_id":45322818814101,"sku":"NHG2B-315A","price":2379.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/ebh1o3tmv-eaton-moeller-disconnector-bt-250-a-ac-690-v-nh1-ac23b-3p-iec_30977d4e-a472-41ca-a26c-40c9cec7cd5d.jpg?v=1724404252"},{"product_id":"aptsa-80a-fuse-link-for-keto-1","title":"APTSA 80A fuse link for KETO 1","description":"\u003cdiv data-mce-fragment=\"1\" class=\"warning\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\n\u003ch3\u003eAPTSA 80A Fuse Link for KETO 1 - Reliable Overcurrent Protection for Inverter-Battery Systems\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePart No:\u003c\/strong\u003e NHG1B-FUSE-80A\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Storage Systems - Battery Fuses\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe APTSA 80A Fuse Link is designed to provide essential overcurrent protection for inverter-battery systems, ensuring safe and reliable operation. This fuse is compatible with NH1 (size 1) fuse holders, making it an ideal choice for various energy storage systems. Built to meet industrial standards, it offers excellent performance in protecting your equipment from dangerous electrical faults.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e80A Overcurrent Protection:\u003c\/strong\u003e Designed to safeguard your inverter-battery systems from potential overcurrent issues, ensuring system safety and longevity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Industrial-grade fuse link, ensuring robust protection under demanding conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand Flexibility:\u003c\/strong\u003e Typically supplied by Eaton Bussmann, though Mersen may be substituted in case of stock shortages.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Usage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInverter-battery systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Holder Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNH1 (Size 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEaton Bussmann (or Mersen)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQualified electrician\/technician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eInstallation and Usage:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe 80A fuse link is suitable for protecting inverter-battery systems and must be installed by a qualified electrician or technician. It is compatible with NH1 fuse holders, making it easy to integrate into your existing systems for reliable protection against overcurrent.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Notes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the fuse link matches your system’s current and voltage ratings.\u003c\/li\u003e\n\u003cli\u003eInstallation must adhere to local wiring regulations and safety standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Eaton-125NHG01B-NH%20FUSE%20125A%20500V%20GG-GL%20SIZE%2001-en_GB.pdf\" target=\"_blank\"\u003eData Sheet 125A Eaton Bussmann Fuse Link For Keto 1\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/bus-ele-an-10507-hsf.pdf\" target=\"_blank\"\u003eInstallation Manual Eaton bussmann fuse selection guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/DC%20Rating.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Advanced Product Technology","offers":[{"title":"Default Title","offer_id":45322818846869,"sku":"NHG1B-FUSE-80A","price":129.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/80NHG01BI-400_L.jpg?v=1724403311"},{"product_id":"aptsa-250a-fuse-link-for-keto-1","title":"APTSA 250A fuse link for KETO 1","description":"\u003ch3\u003eAPTSA 250A Fuse Link for KETO 1 - Industrial-Grade Overcurrent Protection\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePart No:\u003c\/strong\u003e NHG1B-FUSE-250A\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Storage Systems - Battery Fuses\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe APTSA 250A Fuse Link is designed to provide robust overcurrent protection for inverter-battery systems, ensuring safe and efficient operation. Specifically engineered for use with the NH1 (size 1) fuse holder, this fuse link offers reliable protection by disconnecting circuits when current surpasses safe thresholds. Ideal for industrial applications, it enhances the safety and longevity of energy storage systems.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e250A Overcurrent Protection:\u003c\/strong\u003e Guards your inverter-battery system from damage due to overcurrent, ensuring long-term operational safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNH1 Fuse Holder Compatibility:\u003c\/strong\u003e Perfectly fits into NH1 (size 1) fuse holders for a secure and dependable installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable and Reliable:\u003c\/strong\u003e Built to handle heavy electrical loads, making it suitable for demanding energy storage applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable Brand Availability:\u003c\/strong\u003e Typically supplied by Eaton Bussmann, with Mersen as an alternative depending on stock availability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Holder Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNH1 (Size 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEaton Bussmann (or equivalent Mersen)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQualified electrician\/technician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eInstallation and Usage:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe 250A fuse link is a critical safety component in preventing overcurrent issues in inverter-battery systems. It is essential to ensure that this fuse is compatible with your system's operating limits and installed by a qualified technician for maximum safety and performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Notes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDouble-check the compatibility with your inverter and battery operating parameters before selecting the fuse.\u003c\/li\u003e\n\u003cli\u003eAlways adhere to local electrical codes and safety standards to ensure proper protection and system longevity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"warning\" data-mce-fragment=\"1\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Eaton-250NHG1B-NH%20FUSE%20250A%20500V%20GG-GL%20SIZE%201-en_GB.pdf\" target=\"_blank\"\u003eData Sheet 250A Eaton Bussmann Fuse Link For Keto 1\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/bus-ele-an-10507-hsf.pdf\" target=\"_blank\"\u003eInstallation Manual Eaton bussmann fuse selection guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/DC%20Rating.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/div\u003e","brand":"Advanced Product Technology","offers":[{"title":"Default Title","offer_id":45322818879637,"sku":"NHG1B-FUSE-250A","price":169.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/7841949_ew370_eh370.png?v=1724401665"},{"product_id":"aptsa-200a-fuse-link-for-keto-1","title":"APTSA 200A fuse link for KETO 1","description":"\u003cdiv data-mce-fragment=\"1\" class=\"warning\"\u003e\n\u003ch3\u003eAPTSA 200A Fuse Link for KETO 1 - High-Performance Overcurrent Protection\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePart No:\u003c\/strong\u003e NHG1B-FUSE-200A\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Storage Systems - Battery Fuses\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe APTSA 200A Fuse Link is designed to protect inverter-battery systems from overcurrent faults. It offers industrial-grade protection, ensuring the safe operation of energy storage systems by disconnecting power when current exceeds safe levels. This fuse link is compatible with the NH1 (size 1) fuse holder, providing a secure fit for various applications.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e200A Overcurrent Protection:\u003c\/strong\u003e Protects against excessive current, safeguarding your inverter-battery system from potential damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNH1 Fuse Holder Compatibility:\u003c\/strong\u003e Designed for use with the NH1 (size 1) fuse holder, ensuring versatility across different systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Engineered to withstand high electrical loads, making it suitable for robust energy storage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand Variability:\u003c\/strong\u003e While Eaton Bussmann is the primary supplier, alternate brands like Mersen may be provided due to stock availability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Holder Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNH1 (Size 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEaton Bussmann (or equivalent Mersen)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQualified electrician\/technician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eInstallation and Usage:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe 200A fuse link ensures optimal protection for inverter-battery systems by disconnecting the circuit during overcurrent events. For proper installation, ensure the fuse is compatible with your system's operational limits and is installed by a qualified technician.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Notes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm compatibility with your inverter-battery system before installation.\u003c\/li\u003e\n\u003cli\u003eEnsure compliance with local electrical codes to maintain system integrity and protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Eaton-200NHG1B-NH%20FUSE%20200A%20500V%20GG-GL%20SIZE%201-en_GB.pdf\" target=\"_blank\"\u003eData Sheet 200A Eaton Bussmann Fuse Link For Keto 1\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/bus-ele-an-10507-hsf.pdf\" target=\"_blank\"\u003eInstallation Manual Eaton bussmann fuse selection guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/DC%20Rating.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Advanced Product Technology","offers":[{"title":"Default Title","offer_id":45322818912405,"sku":"NHG1B-FUSE-200A","price":109.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/spd_fe545a39fd_b.jpg?v=1724401386"},{"product_id":"aptsa-160a-fuse-link-for-keto-1","title":"APTSA 160A fuse link for KETO 1","description":"\u003cdiv class=\"warning\" data-mce-fragment=\"1\"\u003e\n\u003ch3\u003eAPTSA 160A Fuse Link for KETO 1 - Industrial Overcurrent Protection\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePart No:\u003c\/strong\u003e NHG1B-FUSE-160A\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Storage Systems - Battery Fuses\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe APTSA 160A Fuse Link is engineered for robust overcurrent protection in inverter-battery systems. Designed to be used with the NH1 (size 1) fuse holder, it ensures the safety and efficiency of power systems by interrupting excessive currents during fault conditions.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e160A Overcurrent Protection:\u003c\/strong\u003e Safeguards your inverter-battery system by preventing damage from overcurrent situations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNH1 Fuse Holder Compatibility:\u003c\/strong\u003e Specifically designed for use with NH1 (size 1) fuse holders, making it ideal for a variety of energy storage and inverter applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial-Grade Performance:\u003c\/strong\u003e Built for high voltage DC systems, ensuring reliable protection under heavy loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand Flexibility:\u003c\/strong\u003e Supplied primarily as Eaton Bussmann, but may vary to Mersen or other equivalent brands depending on stock availability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Holder Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNH1 (Size 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEaton Bussmann (or equivalent Mersen)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQualified electrician\/technician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eInstallation and Usage:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe APTSA 160A fuse link is a vital component for protecting your inverter-battery system from dangerous overcurrent scenarios. To ensure safety and functionality, the fuse link must be installed by a qualified electrician or technician, adhering to local wiring regulations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Notes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify compatibility with your system's operational parameters before installation.\u003c\/li\u003e\n\u003cli\u003eInstallation must meet local electrical codes and standards to guarantee proper protection and performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Eaton-160NHG01B-NH%20FUSE%20160A%20500V%20GG-GL%20SIZE%2001-en_GB.pdf\" target=\"_blank\"\u003eData Sheet 160A Eaton Bussmann Fuse Link For Keto 1\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/bus-ele-an-10507-hsf.pdf\" target=\"_blank\"\u003eInstallation Manual Eaton bussmann fuse selection guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/DC%20Rating.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Advanced Product Technology","offers":[{"title":"Default Title","offer_id":45322818945173,"sku":"NHG1B-FUSE-160A","price":69.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/spd_1c2c299707_b.jpg?v=1724401058"},{"product_id":"aptsa-125a-fuse-link-for-keto-1","title":"APTSA 125A fuse link for KETO 1","description":"\u003cdiv class=\"warning\" data-mce-fragment=\"1\"\u003e\n\u003ch3\u003eAPTSA 125A Fuse Link for KETO 1 - Robust Overcurrent Protection\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePart No:\u003c\/strong\u003e NHG1B-FUSE-125A\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Storage Systems - Battery Fuses\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe APTSA 125A Fuse Link is engineered to safeguard inverter-battery systems from overcurrent scenarios, providing a crucial layer of protection. This fuse link is compatible with the NH1 (size 1) fuse holder, ensuring a perfect fit for your energy storage solutions.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e125A Overcurrent Protection:\u003c\/strong\u003e Safeguards inverter-battery systems by interrupting excessive current during faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNH1 Fuse Holder Compatibility:\u003c\/strong\u003e Designed for use with NH1 (size 1) fuse holders.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand Flexibility:\u003c\/strong\u003e While typically supplied as Eaton Bussmann, equivalent brands such as Mersen may be provided due to stock variations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Holder Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNH1 (Size 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEaton Bussmann (or equivalent Mersen)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eInstallation and Usage:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThis fuse link is critical for protecting your inverter-battery system from overcurrent conditions. A qualified electrician or technician must carry out the installation to ensure optimal protection and compliance with local wiring standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Notes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the inverter and battery operating limits are compatible with the 125A rating of this fuse link.\u003c\/li\u003e\n\u003cli\u003eProper installation following local regulations is essential for the system's safety and performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Eaton-125NHG01B-NH%20FUSE%20125A%20500V%20GG-GL%20SIZE%2001-en_GB.pdf\" target=\"_blank\"\u003eData Sheet 125A Eaton Bussmann Fuse Link For Keto 1\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/bus-ele-an-10507-hsf.pdf\" target=\"_blank\"\u003eInstallation Manual Eaton bussmann fuse selection guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/DC%20Rating.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Advanced Product Technology","offers":[{"title":"Default Title","offer_id":45322818977941,"sku":"NHG1B-FUSE-125A","price":69.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/OIP_96ee0ec7-3ac6-4ead-8cc5-697e318d5587.jpg?v=1724400658"},{"product_id":"aptsa-100a-fuse-link-for-keto-1","title":"APTSA 100A fuse link for KETO 1","description":"\u003cdiv class=\"flex max-w-full flex-col flex-grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"b9d23bbd-1397-4b03-bd06-6e462b1ece31\" dir=\"auto\" class=\"min-h-[20px] text-message flex w-full flex-col items-end gap-2 break-words [.text-message+\u0026amp;]:mt-5 overflow-x-auto whitespace-pre-wrap\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[3px]\"\u003e\n\u003cdiv class=\"markdown prose w-full break-words dark:prose-invert light\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"warning\" data-mce-fragment=\"1\"\u003e\n\u003ch3\u003eAPTSA 100A Fuse Link for KETO 1 - Reliable Overcurrent Protection\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePart No:\u003c\/strong\u003e NHG1B-FUSE-100A\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Storage Systems - Battery Fuses\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe APTSA 100A Fuse Link is designed to provide essential overcurrent protection for inverter-battery systems. This fuse link is compatible with the NH1 (size 1) fuse holder and is ideal for preventing damage to your energy storage components by interrupting excessive current flow during faults.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e100A Overcurrent Protection:\u003c\/strong\u003e Protects inverter-battery systems from damage due to excessive current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNH1 Fuse Holder Compatibility:\u003c\/strong\u003e Specifically designed for use with the NH1 (size 1) fuse holder.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand Flexibility:\u003c\/strong\u003e Typically supplied as Eaton Bussmann but may be substituted with equivalent brands such as Mersen due to stock availability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Holder Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNH1 (Size 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEaton Bussmann (or equivalent Mersen)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eInstallation and Usage:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThis fuse link must be installed by a qualified electrician or technician to ensure it provides the necessary protection for your inverter-battery system. Verify that the inverter and battery operating limits are within the fuse's rated capacity before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Notes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure compatibility with your system's voltage and current requirements before selecting this fuse link.\u003c\/li\u003e\n\u003cli\u003eInstallation must be performed according to local wiring regulations and standards to guarantee system safety and compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Eaton-125NHG01B-NH%20FUSE%20125A%20500V%20GG-GL%20SIZE%2001-en_GB.pdf\" target=\"_blank\"\u003eData Sheet 125A Eaton Bussmann Fuse Link For Keto 1\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/bus-ele-an-10507-hsf.pdf\" target=\"_blank\"\u003eInstallation Manual Eaton bussmann fuse selection guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/DC%20Rating.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/div\u003e","brand":"Advanced Product Technology","offers":[{"title":"Default Title","offer_id":45322819043477,"sku":"NHG1B-FUSE-100A","price":49.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/NHG1B-FUSE-100A.png?v=1724400393"},{"product_id":"aptsa-battery-disconnector-with-250a-fuses","title":"APTSA Battery Disconnector with 250A Fuses","description":"\u003cdiv class=\"prod_composite\" data-mce-fragment=\"1\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"TextSummary\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"warning\" data-mce-fragment=\"1\"\u003e\n\u003ch3\u003eAPTSA Battery Disconnector with 250A Fuses - High-Capacity Battery Isolation and Overcurrent Protection\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePart No:\u003c\/strong\u003e NHG1B-250A\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Storage Systems - Battery Fuse Holder\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe APTSA Battery Disconnector with 250A fuses is a crucial component for high-capacity inverter-battery systems, providing both overcurrent protection and isolation. This assembly includes a KETO size 1 fuse-switch-disconnector and two 250A fuse links, designed for efficient performance and safety in large energy storage setups.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e250A Overcurrent Protection:\u003c\/strong\u003e The included 250A fuse links ensure protection from overcurrent in inverter-battery systems, safeguarding your equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Isolation:\u003c\/strong\u003e The fuse-switch-disconnector allows safe isolation of the battery system during maintenance or in the event of an emergency, improving operational safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Components:\u003c\/strong\u003e The disconnector and fuse links are constructed from robust materials, ensuring reliability and long-term performance in demanding environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Sourcing:\u003c\/strong\u003e The fuse links are primarily sourced from Eaton Bussmann, with Mersen offered as an alternative depending on stock availability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisconnector Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNH1 (Size 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Usage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInverter-battery systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded Components\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKETO Size 1 Body, 2 x 250A Fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Link Brand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEaton Bussmann \/ Mersen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQualified electrician\/technician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eInstallation and Usage:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe APTSA Battery Disconnector with 250A fuses is ideal for large-scale battery systems, providing reliable overcurrent protection and secure isolation for safe system management. Compatible with NH1 fuse holders, it supports a wide range of inverter-battery configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Notes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure that the selected fuse rating matches the requirements of your inverter-battery system.\u003c\/li\u003e\n\u003cli\u003eInstallation by a qualified electrician or technician is required.\u003c\/li\u003e\n\u003cli\u003eAll installations must comply with local wiring regulations and standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis 250A battery disconnector provides reliable protection and isolation, making it essential for managing safety in high-capacity energy storage systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Eaton-200NHG1B-NH%20FUSE%20200A%20500V%20GG-GL%20SIZE%201-en_GB.pdf\" target=\"_blank\"\u003eData Sheet 200A Eaton Bussmann Fuse Link For Keto 1\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/DC%20Rating.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Advanced Product Technology","offers":[{"title":"Default Title","offer_id":45322819076245,"sku":"NHG1B-250A","price":1549.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/ebh1o3tmv-eaton-moeller-disconnector-bt-250-a-ac-690-v-nh1-ac23b-3p-iec_c0191de6-f99e-4229-a52d-e6a2ee84e7c9.jpg?v=1724404152"},{"product_id":"aptsa-battery-disconnector-with-200a-fuses","title":"APTSA Battery Disconnector with 200A Fuses","description":"\u003cdiv class=\"prod_composite\" data-mce-fragment=\"1\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"TextSummary\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"warning\" data-mce-fragment=\"1\"\u003e\n\u003ch3\u003eAPTSA Battery Disconnector with 200A Fuses - Comprehensive Battery Isolation and Overcurrent Protection\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePart No:\u003c\/strong\u003e NHG1B-200A\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Storage Systems - Battery Fuse Holder\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe APTSA Battery Disconnector with 200A fuses is an essential component for ensuring both overcurrent protection and battery isolation in inverter-battery systems. This assembly includes a KETO size 1 fuse-switch-disconnector and two 200A fuse links, providing robust protection and reliability in high-power applications.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e200A Overcurrent Protection:\u003c\/strong\u003e Equipped with 200A fuse links, this product offers solid protection for inverter-battery systems against excessive current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Isolation:\u003c\/strong\u003e The fuse-switch-disconnector allows safe and reliable isolation of the battery, enhancing maintenance and safety procedures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuality Components:\u003c\/strong\u003e Built with high-quality materials, the disconnector and fuse setup ensures dependable performance in energy storage applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Sourcing:\u003c\/strong\u003e The fuse links are primarily sourced from Eaton Bussmann, with Mersen as a secondary option due to availability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisconnector Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNH1 (Size 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Usage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInverter-battery systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded Components\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKETO Size 1 Body, 2 x 200A Fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Link Brand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEaton Bussmann \/ Mersen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQualified electrician\/technician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eInstallation and Usage:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe APTSA Battery Disconnector with 200A fuses is ideal for protecting battery storage systems from overcurrent while offering safe isolation during servicing or emergencies. It is compatible with NH1 fuse holders and supports a variety of inverter-battery configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Notes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the fuse rating matches your system's requirements.\u003c\/li\u003e\n\u003cli\u003eThis product must be installed by a qualified electrician or technician.\u003c\/li\u003e\n\u003cli\u003eAdherence to local wiring regulations and standards is mandatory for safe installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis battery disconnector with 200A fuses is engineered to provide safety, reliability, and ease of use in energy storage systems, making it a key component for managing battery protection and isolation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Eaton-200NHG1B-NH%20FUSE%20200A%20500V%20GG-GL%20SIZE%201-en_GB.pdf\" target=\"_blank\"\u003eData Sheet 200A Eaton Bussmann Fuse Link For Keto 1\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/DC%20Rating.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Advanced Product Technology","offers":[{"title":"Default Title","offer_id":45322819174549,"sku":"NHG1B-200A","price":1409.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/ebh1o3tmv-eaton-moeller-disconnector-bt-250-a-ac-690-v-nh1-ac23b-3p-iec_e71a8f4c-c5f1-4185-8f28-7ab0ba9caabc.jpg?v=1724403986"},{"product_id":"aptsa-battery-disconnector-with-160a-fuses","title":"APTSA Battery Disconnector with 160A Fuses","description":"\u003cdiv class=\"prod_composite\" data-mce-fragment=\"1\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"TextSummary\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"warning\" data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003ch3\u003eAPTSA Battery Disconnector with 160A Fuses - Battery Isolation and Overcurrent Protection\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePart No:\u003c\/strong\u003e NHG1B-160A\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Storage Systems - Battery Fuse Holder\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe APTSA Battery Disconnector with 160A fuses is designed to provide both battery isolation and overcurrent protection in inverter-battery systems. The kit includes a fuse-switch-disconnector KETO size 1 body and two 160A fuse links, ensuring optimal safety and protection for your energy storage setup. This product safeguards the system from overcurrent conditions while allowing for safe isolation when necessary.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e160A Overcurrent Protection:\u003c\/strong\u003e Includes 160A fuse links to protect the inverter-battery systems from excessive current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Isolation Capability:\u003c\/strong\u003e The integrated fuse-switch-disconnector ensures safe isolation of the battery during maintenance or emergency conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Designed for reliability, the disconnector and fuse setup is ideal for use in high-demand energy storage applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand Variability:\u003c\/strong\u003e The primary brand for the fuse links is Eaton Bussmann, but Mersen may be supplied due to stock availability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisconnector Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNH1 (Size 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Usage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInverter-battery systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded Components\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKETO Size 1 Body, 2 x 160A Fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Link Brand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEaton Bussmann \/ Mersen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQualified electrician\/technician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eInstallation and Usage:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe APTSA Battery Disconnector with 160A fuses is essential for providing both isolation and protection in battery storage systems. It is compatible with NH1 fuse holders and is suitable for integration into various inverter-battery systems, ensuring system safety and compliance with local standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Notes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the fuse rating is appropriate for your system’s specifications.\u003c\/li\u003e\n\u003cli\u003eInstallation by a qualified electrician or technician is required.\u003c\/li\u003e\n\u003cli\u003eFollow all local wiring regulations and standards during installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis combination of a disconnector and 160A fuses ensures both safety and reliability for energy storage systems, offering critical overcurrent protection and the ability to safely isolate the battery when needed.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Eaton-200NHG1B-NH%20FUSE%20200A%20500V%20GG-GL%20SIZE%201-en_GB.pdf\" target=\"_blank\"\u003eData Sheet 200A Eaton Bussmann Fuse Link For Keto 1\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/DC%20Rating.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Advanced Product Technology","offers":[{"title":"Default Title","offer_id":45322819207317,"sku":"NHG1B-160A","price":1339.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/ebh1o3tmv-eaton-moeller-disconnector-bt-250-a-ac-690-v-nh1-ac23b-3p-iec_4e0d88e0-55bd-4336-bd91-2f5b152d901b.jpg?v=1724403817"},{"product_id":"aptsa-battery-disconnector-with-125a-fuses","title":"APTSA Battery Disconnector with 125A Fuses","description":"\u003cdiv class=\"prod_composite\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"compositeHeading\" data-mce-fragment=\"1\"\u003e\n\u003ch3\u003eAPTSA Battery Disconnector with 125A Fuses - Battery Isolation and Protection\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePart No:\u003c\/strong\u003e NHG1B-125A\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Storage Systems - Battery Fuse Holder\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe APTSA Battery Disconnector with 125A fuses is an essential component for inverter-battery systems, providing reliable overcurrent protection and battery isolation. This part includes a fuse-switch-disconnector KETO size 1 body (battery isolator) and two 125A fuse links. Ideal for maintaining system safety and efficiency, this product ensures that the inverter and battery are safeguarded against excessive current.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e125A Overcurrent Protection:\u003c\/strong\u003e The 125A fuse links protect inverter-battery systems from overcurrent conditions, preserving the integrity of the equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Isolation:\u003c\/strong\u003e The fuse-switch-disconnector allows for the safe isolation of the battery, providing a crucial safeguard during maintenance or emergency scenarios.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Design:\u003c\/strong\u003e Built for robustness, this disconnector and fuse combo is suitable for demanding applications in energy storage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand Flexibility:\u003c\/strong\u003e Eaton Bussmann is the primary supplier, with Mersen as an alternative brand depending on availability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisconnector Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNH1 (Size 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Usage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInverter-battery systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded Components\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKETO Size 1 Body, 2 x 125A Fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Link Brand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEaton Bussmann \/ Mersen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQualified electrician\/technician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eInstallation and Usage:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThis product is designed for safe integration into inverter-battery systems, providing both isolation and overcurrent protection. The fuse-switch-disconnector is suitable for high-demand energy storage setups, ensuring reliable performance and safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Notes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the fuse link rating matches your system’s specifications.\u003c\/li\u003e\n\u003cli\u003eInstallation by a qualified electrician or technician is mandatory.\u003c\/li\u003e\n\u003cli\u003eFollow local wiring regulations and standards to ensure safe and compliant installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis disconnector and fuse setup is critical for ensuring the operational safety of energy storage systems, offering both protection and easy isolation when necessary.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"TextSummary\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"warning\" data-mce-fragment=\"1\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/nh-gear-catalogue_ca132061en-V2.pdf\" target=\"_blank\"\u003eBrochure Eaton Bussmann\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/Eaton-200NHG1B-NH%20FUSE%20200A%20500V%20GG-GL%20SIZE%201-en_GB.pdf\" target=\"_blank\"\u003eData Sheet 200A Eaton Bussmann Fuse Link For Keto 1\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.segensolar.co.za\/reseller\/docs\/DC%20Rating.pdf\" target=\"_blank\"\u003eTechnical Data DC Voltage rating\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Advanced Product Technology","offers":[{"title":"Default Title","offer_id":45322819240085,"sku":"NHG1B-125A","price":1339.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/3250\/5493\/files\/ebh1o3tmv-eaton-moeller-disconnector-bt-250-a-ac-690-v-nh1-ac23b-3p-iec.jpg?v=1724403698"}],"url":"https:\/\/naqo.co.za\/collections\/battery-fuses-and-holders.oembed?page=2","provider":"Naqo","version":"1.0","type":"link"}